Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 670646

The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC


Chatrchyan, S.; ...; Godinović, Nikola; Lelas, Damir; Pleština, Roko; Polić, Dunja; Puljak, Ivica; Antunović, Željko; Kovač, Marko; Brigljević, Vuko et al.
The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC // Journal of instrumentation, 8 (2013), P11002-1 doi:10.1088/1748-0221/8/11/P11002 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 670646 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC

Autori
Chatrchyan, S. ; ... ; Godinović, Nikola ; Lelas, Damir ; Pleština, Roko ; Polić, Dunja ; Puljak, Ivica ; Antunović, Željko ; Kovač, Marko ; Brigljević, Vuko ; Đurić, Senka ; Kadija, Krešo ; Luetić, Jelena ; Morović, Srećko ; Mekterović, Darko ; ... ; Swanson, J.

Izvornik
Journal of instrumentation (1748-0221) 8 (2013); P11002-1

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Muon spectrometers; Particle tracking detectors; Particle tracking detectors (Gaseous detectors)

Sažetak
The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 inverse picobarns. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 micrometers in the DTs, 40-150 micrometers in the CSCs, and 0.8-1.2 centimeters in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
023-0982887-3064 - Potraga za Higgsovim bozonom i novom fizikom detektorom CMS (Puljak, Ivica, MZOS ) ( CroRIS)
098-0982887-2878 - Eksperimentalna fizika na LHC energijama (Kadija, Krešo, MZOS ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi iopscience.iop.org

Citiraj ovu publikaciju:

Chatrchyan, S.; ...; Godinović, Nikola; Lelas, Damir; Pleština, Roko; Polić, Dunja; Puljak, Ivica; Antunović, Željko; Kovač, Marko; Brigljević, Vuko et al.
The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC // Journal of instrumentation, 8 (2013), P11002-1 doi:10.1088/1748-0221/8/11/P11002 (međunarodna recenzija, članak, znanstveni)
Chatrchyan, S., ..., Godinović, N., Lelas, D., Pleština, R., Polić, D., Puljak, I., Antunović, Ž., Kovač, M. & Brigljević, V. (2013) The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC. Journal of instrumentation, 8, P11002-1 doi:10.1088/1748-0221/8/11/P11002.
@article{article, author = {Chatrchyan, S. and Godinovi\'{c}, Nikola and Lelas, Damir and Ple\v{s}tina, Roko and Poli\'{c}, Dunja and Puljak, Ivica and Antunovi\'{c}, \v{Z}eljko and Kova\v{c}, Marko and Brigljevi\'{c}, Vuko and \DJuri\'{c}, Senka and Kadija, Kre\v{s}o and Lueti\'{c}, Jelena and Morovi\'{c}, Sre\'{c}ko and Mekterovi\'{c}, Darko and Swanson, J.}, year = {2013}, pages = {P11002-1-P11002-102}, DOI = {10.1088/1748-0221/8/11/P11002}, keywords = {Muon spectrometers, Particle tracking detectors, Particle tracking detectors (Gaseous detectors)}, journal = {Journal of instrumentation}, doi = {10.1088/1748-0221/8/11/P11002}, volume = {8}, issn = {1748-0221}, title = {The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC}, keyword = {Muon spectrometers, Particle tracking detectors, Particle tracking detectors (Gaseous detectors)} }
@article{article, author = {Chatrchyan, S. and Godinovi\'{c}, Nikola and Lelas, Damir and Ple\v{s}tina, Roko and Poli\'{c}, Dunja and Puljak, Ivica and Antunovi\'{c}, \v{Z}eljko and Kova\v{c}, Marko and Brigljevi\'{c}, Vuko and \DJuri\'{c}, Senka and Kadija, Kre\v{s}o and Lueti\'{c}, Jelena and Morovi\'{c}, Sre\'{c}ko and Mekterovi\'{c}, Darko and Swanson, J.}, year = {2013}, pages = {P11002-1-P11002-102}, DOI = {10.1088/1748-0221/8/11/P11002}, keywords = {Muon spectrometers, Particle tracking detectors, Particle tracking detectors (Gaseous detectors)}, journal = {Journal of instrumentation}, doi = {10.1088/1748-0221/8/11/P11002}, volume = {8}, issn = {1748-0221}, title = {The performance of the CMS muon detector in proton-proton collisions at sqrt(s) = 7 TeV at the LHC}, keyword = {Muon spectrometers, Particle tracking detectors, Particle tracking detectors (Gaseous detectors)} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font