Pregled bibliografske jedinice broj: 669811
Misfueling Detection with Two Offseted Capacitive Fuel Senders
Misfueling Detection with Two Offseted Capacitive Fuel Senders // HDKBR info, 10 (2013), 32-38 (podatak o recenziji nije dostupan, članak, znanstveni)
CROSBI ID: 669811 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Misfueling Detection with Two Offseted Capacitive Fuel Senders
Autori
Miljković, Dubravko
Izvornik
HDKBR info (1847-9340) 10
(2013);
32-38
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
misfuel detection; fuel sender
Sažetak
Misfueling of a general aviation aircraft with a Jet Fuel instead of an Avgas can have dire consequences. In this paper simple non- destructive testing method is proposed using two capacitive fuel senders that are vertically displaced in a fuel tank by a small distance to detect such situation. Method is based on different readings for the same fuel level in a tank (as fuel senders are displaced). Each fuel has different dielectric constant. In case of correct fuelling difference between these readings will always fall within narrow fixed interval.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Strojarstvo, Tehnologija prometa i transport
POVEZANOST RADA
Projekti:
135-1352339-2349 - Parametri ekoloških utjecaja na razvoj infrastrukture i transportnih sustava (Bucak, Tino, MZOS ) ( CroRIS)
Ustanove:
Fakultet prometnih znanosti, Zagreb
Profili:
Dubravko Miljković
(autor)