Pregled bibliografske jedinice broj: 66818
Automatic Determination of Deformations at External Fixater in Medicine by Means of Electronic Theodolite
Automatic Determination of Deformations at External Fixater in Medicine by Means of Electronic Theodolite // Proceedings of the 9th FIG International Symposium on Determination Measurements / Kaszmarek, I. (ur.).
Olsztyn: The institute of geodesy, 1999. str. 354-360 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 66818 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Automatic Determination of Deformations at External Fixater in Medicine by Means of Electronic Theodolite
Autori
Boljkovac, Draško ; Solarić, Nikola ; Solarić, Miljenko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 9th FIG International Symposium on Determination Measurements
/ Kaszmarek, I. - Olsztyn : The institute of geodesy, 1999, 354-360
Skup
International Symposium on Determination Measurements (9 ; 1999)
Mjesto i datum
Olsztyn, Poljska, 27.09.1999. - 30.09.1999
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
precise testing of external fixateur
Sažetak
At this paper is presented an automatic determination of deformations at a fixater in medicine by means of an electronic theodolite Kern E2 and notebook. We determined some shifts measured points on the Ilizarovs external fixaters and model of thigt-bone fixed by ones, under load of different directions and magnitudes. We compared some shifts at classic and hybrid form Ilizarovs external frame. The distance between the electronic theodolites and the experimental models (model of thigh-bone with external frame) was 2 m. The standard deviation of determinations positions of points at experimental model was 0.006 mm.This method has an advantages in comparison with the methode by means of micrometers-devices. That enables an space determination of deformity the fixaters at numerous points on external frame in three directions. It is not possible by means of micrometers-devices. In comparison with the photogrammetric method this methode with electronic theodolites provides major grade of precision. We had measure some amounts of deformations at experimental models (thigh-bone models with external frames) under load of different directions and magnitudes. Finally, we conclude: some deformations at a hybrid form of Ilizarovs external frame are three times less (300%) than at a classical form. Above described method by means of the electronic theodolites and notebook will enable some testing of any new improved constructins of external frames in the medicine
Izvorni jezik
Engleski
Znanstvena područja
Geodezija