Pregled bibliografske jedinice broj: 664543
Ultrasound-guided percutaneous dilatational tracheostomy : a safe method to avoid cranial misplacement of the tracheostomy tube
Ultrasound-guided percutaneous dilatational tracheostomy : a safe method to avoid cranial misplacement of the tracheostomy tube // Intensive care medicine, 26 (2000), 9; 1379-1381 doi:10.1007/s001340000589 (međunarodna recenzija, kratko priopcenje, znanstveni)
CROSBI ID: 664543 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Ultrasound-guided percutaneous dilatational tracheostomy : a safe method to avoid cranial misplacement of the tracheostomy tube
Autori
Šustić, Alan ; Kovač, Dražen ; Žgaljardić, Zoran ; Župan, Željko ; Krstulović, Božidar
Izvornik
Intensive care medicine (0342-4642) 26
(2000), 9;
1379-1381
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kratko priopcenje, znanstveni
Ključne riječi
ultrasound; percutaneous dilatational tracheostomy; pathoanatomical study
Sažetak
The aim of this investigation was to evaluate the role of ultrasonography in avoiding cranial misplacement of the tracheostomy tube and tracheal ring fractures during percutaneous dilatational tracheostomy (PDT). The tracheas of 26 consecutive ICU patients who had undergone PDT but who later died were removed en bloc at autopsy. The tracheas were opened along the membranous portion and the condition of tracheal rings and the site of tracheostomy macroscopically evaluated. The patients were divided in two groups: group A with 15 patients who underwent "blind" PDT and group B with 11 patients who underwent ultrasound-guided PDT. In five (33%) patients from group A, autopsy revealed that the tracheostomy tube was placed between the cricoid cartilage and the first tracheal ring (cranial misplacement) and in six (43%) patients a fracture of one tracheal ring was found. Cranial misplacement of the tracheostomy tube in patients from group B was not found (P <0.05) and four (36%) patients had a broken tracheal ring (P=NS). The authors maintain that by using ultrasound-guided PDT cranial misplacement of the tracheostomy tube may be entirely avoided.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE