Validation of Point-of-Care Glucose Testing for Diagnosis of Type 2 Diabetes
Validation of Point-of-Care Glucose Testing for Diagnosis of Type 2 Diabetes // International journal of endocrinology, (2013), 206309-1 doi:10.1155/2013/206309 (meÄunarodna recenzija, Älanak, znanstveni)
CROSBI ID: 662159 Za ispravke kontaktirajte CROSBI podrŔku putem web obrasca
Naslov
Validation of Point-of-Care Glucose Testing for Diagnosis of Type 2 Diabetes
Autori
VuÄiÄ LovrenÄiÄ, Marijana ; RadiÅ”iÄ Biljak, Vanja ; BožiÄeviÄ, Sandra ; Pape-MedvidoviÄ, Edita ; LjubiÄ, Spomenka
Izvornik
International journal of endocrinology (1687-8337)
(2013);
206309-1
Vrsta, podvrsta i kategorija rada
Radovi u Äasopisima, Älanak, znanstveni
KljuÄne rijeÄi
point-of-care; glucose; type 2 diabetes; diagnosis; oGTT
Sažetak
Point-of-care (POC) glucose technology is currently considered to be insufficiently accurate for the diagnosis of diabetes. The objective of this study was to investigate the diagnostic accuracy of an innovative, interference-resistant POC glucose meter (StatStrip glucose hospital meter, Nova Biomedical, USA) in subjects with a previous history of dysglycaemia, undergoing a 75āg diagnostic oral glucose tolerance test (oGTT). Venous and capillary blood sampling for the reference laboratory procedure (RLP) and POC-glucose measurement was carried out at fasting and 2āh oGTT, and categories of glucose tolerance were classified according to 2006 WHO diagnostic criteria for the respective sample type. We found an excellent between-method correlation at fasting (r = 0.9681, š < 0.0001) and 2āh oGTT (š = 0.9768, š < 0.0001) and an almost perfect diagnostic agreement (weighted Kappaā=ā0.858). Within a total of 237 study subjects, 137 were diagnosed with diabetes with RLP, and only 6 of them were reclassified as having glucose intolerance with POC. The diagnostic performance of POC-fasting glucose in discriminating between the normal and any category of disturbed glucose tolerance did not differ from the RLP (P=0, 081). Results of this study indicate that StatStrip POC glucose meter could serve as a reliable tool for the diabetes diagnosis, particularly in primary healthcare facilities with dispersed blood sampling services.
Izvorni jezik
Engleski
Znanstvena podruÄja
KliniÄke medicinske znanosti
POVEZANOST RADA
Ustanove:
KliniÄka bolnica "Merkur",
Klinika za dijabetes, endokrinologiju i bolesti metabolizma Vuk Vrhovac
Profili:
Edita Pape-MedvidoviÄ
(autor)
Spomenka LjubiÄ
(autor)
Marijana VuÄiÄ LovrenÄiÄ
(autor)
Vanja RadiÅ”iÄ Biljak
(autor)
Citiraj ovu publikaciju:
Äasopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus