The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator


Mirošević, Marija; Maljković, Zlatko; Mišković, Mato
The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator // Procedings on 4th International Conference on Power Engineering, Energy and Electric Drives / Colak, Ilhami (ur.).
Istanbul: Gazi University, 2013. str. 1-5 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 657474 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator

Autori
Mirošević, Marija ; Maljković, Zlatko ; Mišković, Mato

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Procedings on 4th International Conference on Power Engineering, Energy and Electric Drives / Colak, Ilhami - Istanbul : Gazi University, 2013, 1-5

ISBN
978-1-4673-6390-7

Skup
POWERENG2013 - 4th International Conference on Power Engineering, Energy and Electric Drives

Mjesto i datum
Istanbul, Turska, 13.05.2013. - 17.05.2013

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
synchronous generator ; saturation ; cross saturation

Sažetak
The aim of this paper is to explore the effect of implementing of dynamic cross saturation in modeling of synchronous generator. The mathematical model of a saturated salient pole synchronous generator is developed and two cases are analyzed. In the first case the cross- magnetizing phenomenon in the saturated synchronous machine (the magnetic coupling between its direct and quadrature axis) is included, while in the second case the cross-saturation is neglected.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0361616-1617 - Revitalizacija i pogon hidrogeneratora (Maljković, Zlatko, MZO ) ( CroRIS)
275-0361616-1620 - Nove strukture poboljšanja dinamičke stabilnosti hidroagregata (Milković, Mateo, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Sveučilište u Dubrovniku


Citiraj ovu publikaciju:

Mirošević, Marija; Maljković, Zlatko; Mišković, Mato
The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator // Procedings on 4th International Conference on Power Engineering, Energy and Electric Drives / Colak, Ilhami (ur.).
Istanbul: Gazi University, 2013. str. 1-5 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Mirošević, M., Maljković, Z. & Mišković, M. (2013) The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator. U: Colak, I. (ur.)Procedings on 4th International Conference on Power Engineering, Energy and Electric Drives.
@article{article, author = {Miro\v{s}evi\'{c}, Marija and Maljkovi\'{c}, Zlatko and Mi\v{s}kovi\'{c}, Mato}, editor = {Colak, I.}, year = {2013}, pages = {1-5}, keywords = {synchronous generator, saturation, cross saturation}, isbn = {978-1-4673-6390-7}, title = {The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator}, keyword = {synchronous generator, saturation, cross saturation}, publisher = {Gazi University}, publisherplace = {Istanbul, Turska} }
@article{article, author = {Miro\v{s}evi\'{c}, Marija and Maljkovi\'{c}, Zlatko and Mi\v{s}kovi\'{c}, Mato}, editor = {Colak, I.}, year = {2013}, pages = {1-5}, keywords = {synchronous generator, saturation, cross saturation}, isbn = {978-1-4673-6390-7}, title = {The Effect of Implementing of Dynamic Cross Saturation on Modeling of Synchronous Generator}, keyword = {synchronous generator, saturation, cross saturation}, publisher = {Gazi University}, publisherplace = {Istanbul, Turska} }




Contrast