Pregled bibliografske jedinice broj: 654603
Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments
Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments // Analytical chemistry, 86 (2014), 5; 2308-2313 doi:10.1021/ac403558y (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 654603 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Improving the voltammetric quantification of ill- defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments
Autori
Cobelo-Garcia, Antonio ; Santos-Echeandia, Juan ; Lopez-Sanchez, Daniel ; Almecija, Clara ; Omanović, Dario ;
Izvornik
Analytical chemistry (0003-2700) 86
(2014), 5;
2308-2313
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
platinum; signal processing; voltammetry
Sažetak
The determination of trace elements using stripping voltammetry may be seriously affected by the presence of intensive matrix background or interfering peaks, leading to poorer detection limits and/or inaccurate quantitative results. In this work, we have tested the use of signal transformation (e.g., second derivative) in the analysis of platinum in seawater and sediment digests by means of catalytic adsorptive stripping voltammetry. In natural waters, the limit of detection of Pt is affected by a broad background wave due to the formazone complex used in the sample matrix for its determination, while in sediment digests, the Pt peak may be interfered with due to the presence of elevated concentrations of Zn, affecting the accuracy of the determination. Results applying second derivative signal transformation revealed a significant improvement (2–3-fold) of the detection limit in water due to the minimization of background effects, therefore allowing shorter accumulation times and faster determinations. In the presence of interfering peaks, the inaccuracy resulting from erroneous baseline selection in the original signal is eliminated when the second derivative is used. Signal processing should be considered as a useful tool for other voltammetric methodologies where more accurate or faster determinations are needed.
Izvorni jezik
Engleski
Znanstvena područja
Geologija, Kemija
POVEZANOST RADA
Projekti:
098-0982934-2720 - Međudjelovanja oblika tragova metala u vodenom okolišu (Pižeta, Ivanka, MZOS ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb
Profili:
Dario Omanović
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE