Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome


Bosnar D; Kuzmanović Elabjer B; Bušić M; Bjeloš Rončević M; Miletić D; Barać J.
Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome // Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie., 250 (2012), 87-93 doi:10.1007/s00417-011-1771-0 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 653774 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome

Autori
Bosnar D ; Kuzmanović Elabjer B ; Bušić M ; Bjeloš Rončević M ; Miletić D ; Barać J.

Izvornik
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie. (0721-832X) 250 (2012); 87-93

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Pseudoexfoliation syndrome; zonular weakness; optical low-coherence reflectometry

Sažetak
PURPOSE: To evaluate optical ocular components in patients with pseudoexfoliation syndrome using optical low-coherence reflectometry. METHODS: A prospective cohort study of 224 eyes of patients planned for cataract surgery was conducted in the period from January 2009 until July 2009. Patients were divided in two groups: the first group of 47 eyes with cataract complicated with pseudoexfoliation syndrome and the control group of 177 eyes with uncomplicated cataract. Each group was further divided into two subgroups based on its refractive state: emmetropes and hypermetropes. The optical low-coherence reflectometry biometer LENSTAR LS 900 was used to define ocular optical components. RESULTS: A statistically significant difference of ocular optical components was established between the two groups of patients and its matching subgroups: AL (t = 2.25 ; p < 0.05) and ACD (t = 2.24 ; p < 0.05) were significantly higher in the control group, PD was significantly higher in the control group hypermetropes than the PEX group hypermetropes (t = 2.21 ; p < 0.05) while LT (t = 3.01 ; p < 0.001), AST (t = 2.13 ; p < 0.05) and IOL (t = 3.06 ; p < 0.001) were higher in the PEX group of patients than in the control group. CONCLUSIONS: The optical low-coherence reflectometry enabled preoperative detection of zonular weakness and subsequent lens instability documented as a significantly shallower anterior chamber, thicker lens, and smaller pupillary diameter in the pseudoexfoliation syndrome group in the studied population.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
127-0000000-3421 - Mjerenje ishoda i kvalitete života nakon moždanog udara (Kadojić, Dragutin, MZOS ) ( CroRIS)

Ustanove:
Klinički bolnički centar Osijek

Profili:

Avatar Url Josip Barać (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Bosnar D; Kuzmanović Elabjer B; Bušić M; Bjeloš Rončević M; Miletić D; Barać J.
Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome // Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie., 250 (2012), 87-93 doi:10.1007/s00417-011-1771-0 (međunarodna recenzija, članak, znanstveni)
Bosnar D, Kuzmanović Elabjer B, Bušić M, Bjeloš Rončević M, Miletić D & Barać J. (2012) Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie., 250, 87-93 doi:10.1007/s00417-011-1771-0.
@article{article, year = {2012}, pages = {87-93}, DOI = {10.1007/s00417-011-1771-0}, keywords = {Pseudoexfoliation syndrome, zonular weakness, optical low-coherence reflectometry}, journal = {Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv f\"{u}r klinische und experimentelle Ophthalmologie.}, doi = {10.1007/s00417-011-1771-0}, volume = {250}, issn = {0721-832X}, title = {Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome}, keyword = {Pseudoexfoliation syndrome, zonular weakness, optical low-coherence reflectometry} }
@article{article, year = {2012}, pages = {87-93}, DOI = {10.1007/s00417-011-1771-0}, keywords = {Pseudoexfoliation syndrome, zonular weakness, optical low-coherence reflectometry}, journal = {Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv f\"{u}r klinische und experimentelle Ophthalmologie.}, doi = {10.1007/s00417-011-1771-0}, volume = {250}, issn = {0721-832X}, title = {Optical low-coherence reflectometry enables preoperative detection of zonular weakness in pseudoexfoliation syndrome}, keyword = {Pseudoexfoliation syndrome, zonular weakness, optical low-coherence reflectometry} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font