Pregled bibliografske jedinice broj: 65285
A New Two Temperature Humidity Generator as a Primary Standard For Measuring Humidity in Croatia
A New Two Temperature Humidity Generator as a Primary Standard For Measuring Humidity in Croatia // TEMPMEKO '99 Proceedings I / Dubbeldam, Jaco F. ; de Groot, Martin J. (ur.).
Delft: NMi Van Swinden Laboratorium, 1999. str. 203-208 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 65285 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A New Two Temperature Humidity Generator as a Primary Standard For Measuring Humidity in Croatia
Autori
Zvizdić, Davor ; Kolobarić, Vladimir ; Galaso, Ivan ; Šerfezi, Damir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
TEMPMEKO '99
Proceedings I
/ Dubbeldam, Jaco F. ; de Groot, Martin J. - Delft : NMi Van Swinden Laboratorium, 1999, 203-208
Skup
The 7th International Symposium on Temperature and Thermal Measurements in Industry and Science
TEMPMEKO '99
Mjesto i datum
Delft, Nizozemska, 01.06.1999. - 03.06.1999
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
humidity standard; calibration; uncertainty
Sažetak
This paper describes the principle and design of two temperature humidity generator being developed at the Laboratory for Process Measurement. It is designed to eventually operate in dew point range from -15°C to 60°C and in test chamber range to 90°C, thus catering to most of the present demand for calibration in Croatia. The flow through saturator, test chamber and test chamber bypass loop is monitored and set to the desired levels with flow meters and valves. It can be adjusted from fully recirculating flow to fully open circuit flow. Gas saturation degree is determined by measuring the temperature differences between saturator gas outlet and liquid at the saturator inlet. Temperature controllers, thermometers and resistance bridge are connected to computer via digital interfaces and integrated into monitoring and control system on the custom designed, Labview based platform. The initial results of generator evaluation are presented for recirculating mode and for part of the operating range. They include saturator and test chamber responses to stepwise parameter changes and uncertainty estimates in terms of dew point and relative humidity.