Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer


Grzunov, Ana; Leniček Krleža, Jasna
Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer // 13th EFLM Continuous Postgraduate Course in Clinical Chemistry and Laboratory Medicine: New Trends in Diagnosis and Monitoring using POC Instruments / Biochemia Medica, Šimundić, AM (ur.).
Zagreb: Medicinska naklada, 2013. str. A83-A83 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 648715 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer

Autori
Grzunov, Ana ; Leniček Krleža, Jasna

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
13th EFLM Continuous Postgraduate Course in Clinical Chemistry and Laboratory Medicine: New Trends in Diagnosis and Monitoring using POC Instruments / Biochemia Medica, Šimundić, AM - Zagreb : Medicinska naklada, 2013, A83-A83

Skup
13th EFLM Continuous Postgraduate Course in Clinical Chemistry and Laboratory Medicine

Mjesto i datum
Dubrovnik, Hrvatska, 19.10.2013. - 20.10.2013

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
point–of-care; blood gas analyzer; haematology analyzer; haemoglobin; haematocrit

Sažetak
Background: The aim of this study was to compare haemoglobin and haematocrit levels measured as point of care testing and measurements done by automated haematology analyzer. Materials and methods: In this prospective study, haemoglobin and haematocrit levels were measured in 126 consecutive paired arterial or capillary samples using a point of care blood gas analyzer and automated haematology analyzer. Pearson correlation coefficient and Passing-Bablok regression were calculated for the data comparison. Results: Mean (SD) level of haemoglobin measured on blood gas analyzer was 135.59 g/L (26.48) and measured on automated haematology analyzer 118.84 g/L (25.59). The mean difference between the blood gas analyzer and automated haematology analyzer was -16.75 g/L (P < 0.001). Mean (SD) level of haematocrit measured on blood gas analyzer was 0.399 L/L (0.078) and measured on automated haematology analyzer 0.356 L/L (0.071), respectively. The mean difference between the blood gas analyzer and automated haematology analyzer was -0.043 L/L (P < 0.001). Comparison of the results of two devices yielded correlation coefficients r = 0.98 (P < 0.001) for haemoglobin and r = 0.75 (P < 0.001) for haematocrit. Conclusions: Although the correlations between the measurements were significant, blood gas analyzer has shown unacceptable agreement with automated haematology analyzer. It overestimates haemoglobin and haematocrit values, which is not clinically acceptable.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
098-0982464-3120 - Farmakogenetika u dječjoj onkologiji (Stepan Giljević, Jasminka, MZOS ) ( CroRIS)

Ustanove:
Klinika za dječje bolesti Medicinskog fakulteta

Profili:

Avatar Url Jasna Leniček Krleža (autor)

Citiraj ovu publikaciju:

Grzunov, Ana; Leniček Krleža, Jasna
Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer // 13th EFLM Continuous Postgraduate Course in Clinical Chemistry and Laboratory Medicine: New Trends in Diagnosis and Monitoring using POC Instruments / Biochemia Medica, Šimundić, AM (ur.).
Zagreb: Medicinska naklada, 2013. str. A83-A83 (poster, međunarodna recenzija, sažetak, znanstveni)
Grzunov, A. & Leniček Krleža, J. (2013) Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer. U: Biochemia Medica, Šimundić, AM (ur.)13th EFLM Continuous Postgraduate Course in Clinical Chemistry and Laboratory Medicine: New Trends in Diagnosis and Monitoring using POC Instruments.
@article{article, author = {Grzunov, Ana and Leni\v{c}ek Krle\v{z}a, Jasna}, year = {2013}, pages = {A83-A83}, keywords = {point–of-care, blood gas analyzer, haematology analyzer, haemoglobin, haematocrit}, title = {Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer}, keyword = {point–of-care, blood gas analyzer, haematology analyzer, haemoglobin, haematocrit}, publisher = {Medicinska naklada}, publisherplace = {Dubrovnik, Hrvatska} }
@article{article, author = {Grzunov, Ana and Leni\v{c}ek Krle\v{z}a, Jasna}, year = {2013}, pages = {A83-A83}, keywords = {point–of-care, blood gas analyzer, haematology analyzer, haemoglobin, haematocrit}, title = {Comparison of Haemoglobin and Haematocrit Levels On Point of Care Blood Gas Analyzer and Automated Haematology Analyzer}, keyword = {point–of-care, blood gas analyzer, haematology analyzer, haemoglobin, haematocrit}, publisher = {Medicinska naklada}, publisherplace = {Dubrovnik, Hrvatska} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font