Pregled bibliografske jedinice broj: 646938
3D kinematic analysis of croatian women high jump record – 208 cm
3D kinematic analysis of croatian women high jump record – 208 cm // Book of abstracts of 18th annual Congress of the European College of Sport Science, ECSS Barcelona 2013 / Balagué, N., Torrents, C., Vilanova, A., Cadefau, J., Tarragó, R., Tsolakidis, E. (ur.).
Barcelona: European College of Sport Science (ECSS), 2013. str. 157-158 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 646938 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
3D kinematic analysis of croatian women high jump record – 208 cm
Autori
Baković, Marijo ; Antekolović, Ljubomir
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Book of abstracts of 18th annual Congress of the European College of Sport Science, ECSS Barcelona 2013
/ Balagué, N., Torrents, C., Vilanova, A., Cadefau, J., Tarragó, R., Tsolakidis, E. - Barcelona : European College of Sport Science (ECSS), 2013, 157-158
ISBN
978-84-695-7786-8
Skup
18th annual Congress of the European College of Sport Science, ECSS Barcelona 2013
Mjesto i datum
Barcelona, Španjolska, 26.06.2013. - 29.06.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
kinematic parameters; high jump
Sažetak
Croatian record holder for the women’s high jump has been dominant female high jumper in the world for the past several years and she has repeatedly tried to break the world record (2, 09m). The aim of this study was to determine kinematic parameters of the her high jump record which is second best jump in the history of women's high jump (2, 08m). Acquisition of the video recordings necessary for the kinematic analysis was made during IAAF Grand Prix meeting in Zagreb, 31st August 2009. Three digital Sony HDR-HC9E cameras, each with frequency of 50Hz were used. The cameras were recording last two strides of approach, take- off and flight phase. Data analysis were performed according APAS (Ariel Performance Analyses System) protocol standards. Data for the parameters most frequently used in high jump technique studies were calculated. Lengths of the strides (penultimate and last) were 233, 99 and 208, 58cm. Toe to bar distance was 84, 00cm. Take off contact time was 0, 160sec. Horizontal center of mass (CM) velocities: third last stride (6, 89m/s), penultimate stride (7, 06m/s), touchdown (6, 47m/s) and take off (4, 30m/s). Vertical CM velocity at take off was 3, 63m/s. CM heights at: touchdown (99, 73cm), amortization (106, 51cm), take off (130, 05cm), maximum CM height (205, 54cm) and CM height relative to the bar height (-2, 46cm). Knee angle of amortization and angle of take off were 143, 31° and 40, 17°.
Izvorni jezik
Engleski
Znanstvena područja
Pedagogija
POVEZANOST RADA
Projekti:
034-0000000-2340 - Biomehanička efikasnost vrhunskih hrvatskih sportaša (Antekolović, Ljubomir, MZOS ) ( CroRIS)
Ustanove:
Kineziološki fakultet, Zagreb