Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations


Petošić, Antonio; Čorak-Cvjetičanin, Zrinka; Budimir, Marko
Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations // Strojarstvo, 53 (2011), 3; 199-202 doi:620.179.16:681.586.48:681.586.773 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 639651 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations

Autori
Petošić, Antonio ; Čorak-Cvjetičanin, Zrinka ; Budimir, Marko

Izvornik
Strojarstvo (0562-1887) 53 (2011), 3; 199-202

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
non-destructive testing; ultrasound transducer. piezoelectric ceramic; electrical excitation waveform

Sažetak
The electrical excitation dependence of working parameters of a normal beam non-destructive evaluation ultrasound transducer has been investigated. Noteworthy differences between the transducer input electrical impedance and acoustic properties at low excitation voltages (~1V), most often used in electromechanical characterizations by performing frequency sweeps, and at high excitation voltages (~250V), generally used to drive ultrasound transducers in non-destructive evaluation applications, were emphasized. For the purpose of this work, a circular normal beam ultrasound transducer of centre frequency 2 MHz was constructed by using a PZT piezoelectric disk, epoxy-based acoustically passive front matching and backing layers, an electrical impedance matching element, housing and coaxial cable. The transducer was characterized around the thickness extensional vibration mode both by using low and high voltage electrical excitation signals. The characterization of the electromechanical properties was conducted at several different stages of the transducer construction and for several excitation signal waveforms and levels.

Izvorni jezik
Engleski



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
INETEC

Poveznice na cjeloviti tekst rada:

doi Hrčak Hrčak

Citiraj ovu publikaciju:

Petošić, Antonio; Čorak-Cvjetičanin, Zrinka; Budimir, Marko
Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations // Strojarstvo, 53 (2011), 3; 199-202 doi:620.179.16:681.586.48:681.586.773 (međunarodna recenzija, članak, znanstveni)
Petošić, A., Čorak-Cvjetičanin, Z. & Budimir, M. (2011) Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations. Strojarstvo, 53 (3), 199-202 doi:620.179.16:681.586.48:681.586.773.
@article{article, author = {Peto\v{s}i\'{c}, Antonio and \v{C}orak-Cvjeti\v{c}anin, Zrinka and Budimir, Marko}, year = {2011}, pages = {199-202}, DOI = {620.179.16:681.586.48:681.586.773}, keywords = {non-destructive testing, ultrasound transducer. piezoelectric ceramic, electrical excitation waveform}, journal = {Strojarstvo}, doi = {620.179.16:681.586.48:681.586.773}, volume = {53}, number = {3}, issn = {0562-1887}, title = {Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations}, keyword = {non-destructive testing, ultrasound transducer. piezoelectric ceramic, electrical excitation waveform} }
@article{article, author = {Peto\v{s}i\'{c}, Antonio and \v{C}orak-Cvjeti\v{c}anin, Zrinka and Budimir, Marko}, year = {2011}, pages = {199-202}, DOI = {620.179.16:681.586.48:681.586.773}, keywords = {non-destructive testing, ultrasound transducer. piezoelectric ceramic, electrical excitation waveform}, journal = {Strojarstvo}, doi = {620.179.16:681.586.48:681.586.773}, volume = {53}, number = {3}, issn = {0562-1887}, title = {Changes of Working Parameters of a Normal Beam Non-destructive Evaluation Ultrasound Transducer Due to Different Electrical Excitations}, keyword = {non-destructive testing, ultrasound transducer. piezoelectric ceramic, electrical excitation waveform} }