Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 63963

Evaluation of the NOVA-10 STAT/routine chemistry analyzer


Ferenec-Ružić, Dragica; Vrkić, Nada; Blazinić, Franciska; Lazić, N
Evaluation of the NOVA-10 STAT/routine chemistry analyzer // Clinical Chemistry and Laboratory Medicine ; vol 37:Abstracts volume, Special supplement / Siest, Gerard (ur.).
Milano: Walter de Gruyter, 1999. str. S380-S380 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 63963 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of the NOVA-10 STAT/routine chemistry analyzer

Autori
Ferenec-Ružić, Dragica ; Vrkić, Nada ; Blazinić, Franciska ; Lazić, N

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Clinical Chemistry and Laboratory Medicine ; vol 37:Abstracts volume, Special supplement / Siest, Gerard - Milano : Walter de Gruyter, 1999, S380-S380

Skup
IFCC-World Lab, 17th International and 13th European Congress of Clinical Chemistry and Laboratory Medicine

Mjesto i datum
Firenca, Italija, 06.06.1999. - 11.06.1999

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
NOVA-10; electrolyte analyzer; evaluation

Sažetak
The Nova 10 (NOVA Biomedical, Waltham, MA) is an electrolyte analyzer for serum, plasma, CSF and urine testing. It uses a microcomputer-based operating system to measure analytes and calculate both automated and stat-analyses.The aim was to evaluate analytical performance of the instrument according to the ECCLS guidelines (imprecision, accuracy, carry-over, linearity, and comparison studies). Sodium, potassium, chloride, total calcium (tCa) and lithium were evaluated. Control material used in the study Stat Profile Control 1-3, Precinorm U, Precipath U and Serodos. Randomly chosen patient sera were used in comparison study for Na+, K+, Cl- and tCa on the Synchron CX-3 (Beckman), and Li+ on Flame Photometer PHF-104 (Hycel, France). Intra-assay CV was <1% for Na+, K+, Cl-, tCa, and 1.08% for Li+. Inter-assay CV for Na+, K+, Cl-, tCa and Li+ ranged from 1.25%-1.68% respectively. Carry-over was negligible (K<0.01%). Linearity for all analytes was within the declared analytical range. Results of the comparison study (Passing Bablok) showed no statistically significant difference neither for Na+, K+, Cl- and tCa compared with Synchron CX3 (p>0.001), nor for Li+ compared with Flame Photometer. In conclusion, results of the evaluation suggest that NOVA 10 is a precise, accurate and reliable instrument for daily routine.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Farmacija



POVEZANOST RADA


Projekti:
134003

Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
KBC "Sestre Milosrdnice"


Citiraj ovu publikaciju:

Ferenec-Ružić, Dragica; Vrkić, Nada; Blazinić, Franciska; Lazić, N
Evaluation of the NOVA-10 STAT/routine chemistry analyzer // Clinical Chemistry and Laboratory Medicine ; vol 37:Abstracts volume, Special supplement / Siest, Gerard (ur.).
Milano: Walter de Gruyter, 1999. str. S380-S380 (poster, međunarodna recenzija, sažetak, znanstveni)
Ferenec-Ružić, D., Vrkić, N., Blazinić, F. & Lazić, N. (1999) Evaluation of the NOVA-10 STAT/routine chemistry analyzer. U: Siest, G. (ur.)Clinical Chemistry and Laboratory Medicine ; vol 37:Abstracts volume, Special supplement.
@article{article, author = {Ferenec-Ru\v{z}i\'{c}, Dragica and Vrki\'{c}, Nada and Blazini\'{c}, Franciska and Lazi\'{c}, N}, editor = {Siest, G.}, year = {1999}, pages = {S380-S380}, keywords = {NOVA-10, electrolyte analyzer, evaluation}, title = {Evaluation of the NOVA-10 STAT/routine chemistry analyzer}, keyword = {NOVA-10, electrolyte analyzer, evaluation}, publisher = {Walter de Gruyter}, publisherplace = {Firenca, Italija} }
@article{article, author = {Ferenec-Ru\v{z}i\'{c}, Dragica and Vrki\'{c}, Nada and Blazini\'{c}, Franciska and Lazi\'{c}, N}, editor = {Siest, G.}, year = {1999}, pages = {S380-S380}, keywords = {NOVA-10, electrolyte analyzer, evaluation}, title = {Evaluation of the NOVA-10 STAT/routine chemistry analyzer}, keyword = {NOVA-10, electrolyte analyzer, evaluation}, publisher = {Walter de Gruyter}, publisherplace = {Firenca, Italija} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font