Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 639597

Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM


Ferković, Kristina; Hegeduš, Hrvoje
Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM // Abstracts collection on new challenges in the European Area: International Baku Forum of young scientists.
Baku, 2013. str. 130-137 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 639597 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM

Autori
Ferković, Kristina ; Hegeduš, Hrvoje

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Abstracts collection on new challenges in the European Area: International Baku Forum of young scientists. / - Baku, 2013, 130-137

Skup
Baku Forum

Mjesto i datum
Baku, Azerbajdžan, 20.05.2013. - 25.05.2013

Vrsta sudjelovanja
Pozvano predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
Digital Multimeter; Root Mean Square Error; Sampling; Aperture time; Number of Samples

Sažetak
Sampling of a sine waveform with high-resolution integrating DMM with the input parameters, such as aperture, sampling and measurement time, number of bursts, the number of harmonics, expected RMS and measured frequency of a signal can be accurate to 5 ppm. The precision of a measured frequency can highly influence on sampling parameters. The amplitude of expected RMS behaves as sinc function due change of an aperture time. Still the error exists. The alternative method for correction of a root-mean-square value of a measured sine signal due impact of aperture time is presented.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0363081-1650 - Mjerenje elektromagnetskih veličina na etalonskoj razini (Ilić, Damir, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Kristina Ferković (autor)

Avatar Url Hrvoje Hegeduš (autor)

Citiraj ovu publikaciju:

Ferković, Kristina; Hegeduš, Hrvoje
Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM // Abstracts collection on new challenges in the European Area: International Baku Forum of young scientists.
Baku, 2013. str. 130-137 (pozvano predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Ferković, K. & Hegeduš, H. (2013) Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM. U: Abstracts collection on new challenges in the European Area: International Baku Forum of young scientists..
@article{article, author = {Ferkovi\'{c}, Kristina and Hegedu\v{s}, Hrvoje}, year = {2013}, pages = {130-137}, keywords = {Digital Multimeter, Root Mean Square Error, Sampling, Aperture time, Number of Samples}, title = {Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM}, keyword = {Digital Multimeter, Root Mean Square Error, Sampling, Aperture time, Number of Samples}, publisherplace = {Baku, Azerbajd\v{z}an} }
@article{article, author = {Ferkovi\'{c}, Kristina and Hegedu\v{s}, Hrvoje}, year = {2013}, pages = {130-137}, keywords = {Digital Multimeter, Root Mean Square Error, Sampling, Aperture time, Number of Samples}, title = {Correcting rms value of a sine waveform sampled due limited number of periods and determinate aperture time on DMM}, keyword = {Digital Multimeter, Root Mean Square Error, Sampling, Aperture time, Number of Samples}, publisherplace = {Baku, Azerbajd\v{z}an} }




Contrast
Increase Font
Decrease Font
Dyslexic Font