Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 622724

ASTEC Computer Code Application to NPP Krško


Šadek, Siniša
ASTEC Computer Code Application to NPP Krško, 2013. (izvještaj).


CROSBI ID: 622724 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
ASTEC Computer Code Application to NPP Krško

Autori
Šadek, Siniša

Izvornik
FER-ZVNE/SA/DA-TR01/13-0

Vrsta, podvrsta
Ostale vrste radova, izvještaj

Godina
2013

Ključne riječi
ASTEC; NPP; SBO; severe accident

Sažetak
The ASTEC computer code was used to simulate a severe accident sequence in the nuclear power plant Krško. The main focus was on the in-vessel phase of the accident. The model of the plant included the detailed nodalization of primary and secondary circuits without the containment. The core, the reactor coolant system, steam generators, steam lines, feedwater and auxiliary feedwater pipes were modelled as a set of thermal hydraulic volumes connected by junctions, to which heat structures were attached to simulate heat losses to the environment. The ICARE module was used to model the reactor core and the CESAR module to model all the other plant systems: primary and secondary circuit piping, the pressurizer and the steam generators. Pumps, accumulators, pressurizer heaters and spray, safety and relief valves were modelled by the SYSINT module. The analysis was conducted in two steps. First, the steady state calculation was performed in order to confirm the applicability of the plant model and to obtain correct initial conditions for the accident analysis. The second step was the calculation of the station blackout (SBO) accident with the leakage of the primary coolant through degraded reactor coolant pump seals, which was a small LOCA without makeup capability. The analyzed SBO scenario included the loss of both off-site and on-site AC power. The only systems available were passive systems: the accumulators and the turbine driven auxiliary feedwater (AFW) system. Two scenarios were analyzed: one with and one without the AFW. Since the operation of the turbine driven AFW pump was not completely passive because it required operator action to manually control the steam generator downcomer water level, the possibility of the unavailability of any operator actions was taken into account by calculating the sequence without heat removal by the secondary system. The latter scenario, without the AFW, resulted in earlier core damage. In both cases, the accident ended with the core melt and the reactor pressure vessel failure with significant release of hydrogen. At the end, the results of the ASTEC calculation were compared with the results of the RELAP5/SCDAPSIM calculation for the same transient scenario. The results showed a good agreement between predictions of the two codes.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0361590-1589 - Nuklearne elektrane za održivu proizvodnju električne energije (Feretić, Danilo, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Siniša Šadek (autor)


Citiraj ovu publikaciju:

Šadek, Siniša
ASTEC Computer Code Application to NPP Krško, 2013. (izvještaj).
Šadek, S. (2013) ASTEC Computer Code Application to NPP Krško. FER-ZVNE/SA/DA-TR01/13-0. Izvještaj.
@unknown{unknown, author = {\v{S}adek, Sini\v{s}a}, year = {2013}, keywords = {ASTEC, NPP, SBO, severe accident}, title = {ASTEC Computer Code Application to NPP Kr\v{s}ko}, keyword = {ASTEC, NPP, SBO, severe accident} }
@unknown{unknown, author = {\v{S}adek, Sini\v{s}a}, year = {2013}, keywords = {ASTEC, NPP, SBO, severe accident}, title = {ASTEC Computer Code Application to NPP Kr\v{s}ko}, keyword = {ASTEC, NPP, SBO, severe accident} }