Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 6222

Evaluation of the fully automated ACS:180 plus chemiluminiscence system


Vrkić, Nada; Ružić, Dragica; Topić, Elizabeta; Petek, Marijan; Petek, Iva; Tarle, Marko; Lukinac, Ljerka
Evaluation of the fully automated ACS:180 plus chemiluminiscence system // The official publication of Medlab 97 : Abstracts / Vonderschmitt, Dieter J. (ur.).
Basel: Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997. str. 233-233 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 6222 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of the fully automated ACS:180 plus chemiluminiscence system

Autori
Vrkić, Nada ; Ružić, Dragica ; Topić, Elizabeta ; Petek, Marijan ; Petek, Iva ; Tarle, Marko ; Lukinac, Ljerka

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
The official publication of Medlab 97 : Abstracts / Vonderschmitt, Dieter J. - Basel : Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997, 233-233

Skup
12th IFCC Eueopean Congress of Clinical Chemistry

Mjesto i datum
Basel, Švicarska, 17.08.1997. - 22.08.1997

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
ACS:180 plus system; chemiluminescence; comparison study; RIA; IRMA; DELFIA

Sažetak
The ACS:180 plus system is an automated chemiluminescence system that measures the amount of light emitted during a chemiluminescent reaction involving the ACS assays, using acridinium ester as the label and paramagnetic particles for the solid phase. Hormones (T3, T4, FT3, FT4, TSH, LH, FSH, prolactin, total HCG, estradiol, progesterone, testosterone, cortisol), drugs (digoxin, vancomycin, phenobarbital, theophylline, phenytoin, gentamycin), tumor markers (CEA, AFP, ferritin, PSA), IgE and vitamin B12 were evaluated according to the guidelines of ECCLS and of SFBC. The reagents and test definitions were supplied by Ciba Corning. Analytical evaluation was done by measuring intra- and inter-assay precision, accuracy, carry-over, linearity and comparison. Comparison study was made with RIA, IRMA and DELFIA methods. Intra-assay CV for hormones, drugs, tumor markers, IgE and vitamin B12 was 0.42%-3.56%, 0.38%-2.87%, 1.34%-4.81%, 2.45%-3.17% and 2.56%-4.00%, respectively. Inter-assay CV (within 10 days) for hormones, drugs, tumor markers, IgE and vitamin B12 was 1.99%-5.66%, 2.34%-5.45%, 3.43%-7.21%, 4.12%-5.77% and 4.11%-4.99% respectively. Sample to sample carry-over was negligible(K less than 0.01%). Study on dilutions showed good linearity for the analytical range. Results of the comparison study showed satisfactory correlation coefficients for hormones r=0.840 to 0.996, for drugs r=0.993 to 0.998, for tumor markers r=0.961 to 1.000, and for IgE r=0.978. The evaluation showed the ACS:180 PLUS to be a precise, accurate and reliable instrument in laboratory routine.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Farmacija



POVEZANOST RADA


Projekti:
134003

Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Nada Vrkić (autor)

Avatar Url Marko Tarle (autor)

Avatar Url Ljerka Lukinac (autor)

Avatar Url Elizabeta Topić (autor)

Avatar Url Marijan Petek (autor)


Citiraj ovu publikaciju:

Vrkić, Nada; Ružić, Dragica; Topić, Elizabeta; Petek, Marijan; Petek, Iva; Tarle, Marko; Lukinac, Ljerka
Evaluation of the fully automated ACS:180 plus chemiluminiscence system // The official publication of Medlab 97 : Abstracts / Vonderschmitt, Dieter J. (ur.).
Basel: Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997. str. 233-233 (poster, međunarodna recenzija, sažetak, stručni)
Vrkić, N., Ružić, D., Topić, E., Petek, M., Petek, I., Tarle, M. & Lukinac, L. (1997) Evaluation of the fully automated ACS:180 plus chemiluminiscence system. U: Vonderschmitt, D. (ur.)The official publication of Medlab 97 : Abstracts.
@article{article, author = {Vrki\'{c}, Nada and Ru\v{z}i\'{c}, Dragica and Topi\'{c}, Elizabeta and Petek, Marijan and Petek, Iva and Tarle, Marko and Lukinac, Ljerka}, editor = {Vonderschmitt, D.}, year = {1997}, pages = {233-233}, keywords = {ACS:180 plus system, chemiluminescence, comparison study, RIA, IRMA, DELFIA}, title = {Evaluation of the fully automated ACS:180 plus chemiluminiscence system}, keyword = {ACS:180 plus system, chemiluminescence, comparison study, RIA, IRMA, DELFIA}, publisher = {Degra AG, Werbung/Marketing-Services, Rotkreuz}, publisherplace = {Basel, \v{S}vicarska} }
@article{article, author = {Vrki\'{c}, Nada and Ru\v{z}i\'{c}, Dragica and Topi\'{c}, Elizabeta and Petek, Marijan and Petek, Iva and Tarle, Marko and Lukinac, Ljerka}, editor = {Vonderschmitt, D.}, year = {1997}, pages = {233-233}, keywords = {ACS:180 plus system, chemiluminescence, comparison study, RIA, IRMA, DELFIA}, title = {Evaluation of the fully automated ACS:180 plus chemiluminiscence system}, keyword = {ACS:180 plus system, chemiluminescence, comparison study, RIA, IRMA, DELFIA}, publisher = {Degra AG, Werbung/Marketing-Services, Rotkreuz}, publisherplace = {Basel, \v{S}vicarska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font