Evaluation of the fully automated ACS:180 plus chemiluminiscence system
Evaluation of the fully automated ACS:180 plus chemiluminiscence system // The official publication of Medlab 97 : Abstracts / Vonderschmitt, Dieter J. (ur.).
Basel: Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997. str. 233-233 (poster, međunarodna recenzija, sažetak, stručni)
CROSBI ID: 6222 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Evaluation of the fully automated ACS:180 plus chemiluminiscence system
Autori
Vrkić, Nada ; Ružić, Dragica ; Topić, Elizabeta ; Petek, Marijan ; Petek, Iva ; Tarle, Marko ; Lukinac, Ljerka
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni
Izvornik
The official publication of Medlab 97 : Abstracts
/ Vonderschmitt, Dieter J. - Basel : Degra AG, Werbung/Marketing-Services, Rotkreuz, 1997, 233-233
Skup
12th IFCC Eueopean Congress of Clinical Chemistry
Mjesto i datum
Basel, Švicarska, 17.08.1997. - 22.08.1997
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
ACS:180 plus system; chemiluminescence; comparison study; RIA; IRMA; DELFIA
Sažetak
The ACS:180 plus system is an automated chemiluminescence system that measures the amount of light emitted during a chemiluminescent reaction involving the ACS assays, using acridinium ester as the label and paramagnetic particles for the solid phase. Hormones (T3, T4, FT3, FT4, TSH, LH, FSH, prolactin, total HCG, estradiol, progesterone, testosterone, cortisol), drugs (digoxin, vancomycin, phenobarbital, theophylline, phenytoin, gentamycin), tumor markers (CEA, AFP, ferritin, PSA), IgE and vitamin B12 were evaluated according to the guidelines of ECCLS and of SFBC. The reagents and test definitions were supplied by Ciba Corning. Analytical evaluation was done by measuring intra- and inter-assay precision, accuracy, carry-over, linearity and comparison. Comparison study was made with RIA, IRMA and DELFIA methods. Intra-assay CV for hormones, drugs, tumor markers, IgE and vitamin B12 was 0.42%-3.56%, 0.38%-2.87%, 1.34%-4.81%, 2.45%-3.17% and 2.56%-4.00%, respectively. Inter-assay CV (within 10 days) for hormones, drugs, tumor markers, IgE and vitamin B12 was 1.99%-5.66%, 2.34%-5.45%, 3.43%-7.21%, 4.12%-5.77% and 4.11%-4.99% respectively. Sample to sample carry-over was negligible(K less than 0.01%). Study on dilutions showed good linearity for the analytical range. Results of the comparison study showed satisfactory correlation coefficients for hormones r=0.840 to 0.996, for drugs r=0.993 to 0.998, for tumor markers r=0.961 to 1.000, and for IgE r=0.978. The evaluation showed the ACS:180 PLUS to be a precise, accurate and reliable instrument in laboratory routine.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti, Farmacija
POVEZANOST RADA
Projekti:
134003
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
KBC "Sestre Milosrdnice"
Profili:
Nada Vrkić
(autor)
Marko Tarle
(autor)
Ljerka Lukinac
(autor)
Elizabeta Topić
(autor)
Marijan Petek
(autor)