Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers


Petani, Sandra; Topić, Elizabeta; Turčić, Graciela
Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers // Acta clinica Croatica, 36 (1997), 2-3; 109-117 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 6212 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers

Autori
Petani, Sandra ; Topić, Elizabeta ; Turčić, Graciela

Izvornik
Acta clinica Croatica (0353-9466) 36 (1997), 2-3; 109-117

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
MEK-8118K and CELL-DYN 1700CS hematology analyzers; three-part differential count; microscopic method of differentiation

Sažetak
Three-part differential blood count obtained on MEK-8118K (Nihon Kohden) and CELL-DYN (CD) 1700CS (Abbott) hematology analyzers was compared with a reference microscopic method of leukocyte differentiation. A total of 398 physiologically normal and pathologic samples were examined, 129 and 269 of them by evaluation of the differential blood count obtained on MEK-8118K and CD 1700CS analyzers, respectively. Linear regression analysis showed satisfactory coefficients of correlation for lymphocytes (r=0.920 for MEK-8118K and r=0.939 for CD 1700CS) and granulocytes (r=0.940 for MEK-8118K and r=0.924 for CD 1700CS). A considerably lower coefficient of correlation was obtained for the population of mononuclears (r=0.590 for MEK-8118K and r=0.435 for CD 1700CS). Sensitivity and specificity for differential blood count, and the percentage of compatibility of the two methods of differentiation were satisfactory for both analyzers evaluated. Sensitivity and specificity for the MEK-8118K analyzer were 91.0% and 92.0%, and for the CD 1700CS analyzer 92.1% and 88.6%, respectively. The percentage of compatibility was 92.3% for MEK-8118K and 91.1% for CD 1700CS. Evaluation of the instrument "flagging system" for differential blood count showed the messages or flags to be a useful indicator of leukocyte pathologic alterations, pointing to the need of microscopic leukocyte differentiation in the indicated samples. Evaluation of differential blood count obtained on MEK-8118K and CD 1700CS hematology analyzers showed them to be reliable in the screening and differentiation between normal and pathologic differential blood counts.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
134003

Ustanove:
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Elizabeta Topić (autor)


Citiraj ovu publikaciju:

Petani, Sandra; Topić, Elizabeta; Turčić, Graciela
Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers // Acta clinica Croatica, 36 (1997), 2-3; 109-117 (međunarodna recenzija, članak, znanstveni)
Petani, S., Topić, E. & Turčić, G. (1997) Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers. Acta clinica Croatica, 36 (2-3), 109-117.
@article{article, author = {Petani, Sandra and Topi\'{c}, Elizabeta and Tur\v{c}i\'{c}, Graciela}, year = {1997}, pages = {109-117}, keywords = {MEK-8118K and CELL-DYN 1700CS hematology analyzers, three-part differential count, microscopic method of differentiation}, journal = {Acta clinica Croatica}, volume = {36}, number = {2-3}, issn = {0353-9466}, title = {Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers}, keyword = {MEK-8118K and CELL-DYN 1700CS hematology analyzers, three-part differential count, microscopic method of differentiation} }
@article{article, author = {Petani, Sandra and Topi\'{c}, Elizabeta and Tur\v{c}i\'{c}, Graciela}, year = {1997}, pages = {109-117}, keywords = {MEK-8118K and CELL-DYN 1700CS hematology analyzers, three-part differential count, microscopic method of differentiation}, journal = {Acta clinica Croatica}, volume = {36}, number = {2-3}, issn = {0353-9466}, title = {Clinical assessment of differential blood count obtained on MEK-8118K and CD 1700Cs automated hematology analyzers}, keyword = {MEK-8118K and CELL-DYN 1700CS hematology analyzers, three-part differential count, microscopic method of differentiation} }

Časopis indeksira:


  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • Biological Abstracts
  • EMBASE/Excerpta Medica





Contrast
Increase Font
Decrease Font
Dyslexic Font