Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution


Supek, Selma; Aine, Cheryl J.
Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution // IEEE transactions on biomedical engineering, 40 (1993), 6; 529-540 doi:10.1109/10.237672 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 614548 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution
(Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution)

Autori
Supek, Selma ; Aine, Cheryl J.

Izvornik
IEEE transactions on biomedical engineering (0018-9294) 40 (1993), 6; 529-540

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
magnetoencefalography ; spatio-temporal resolution ; model order ; statistical measures of goodness-of-fit ; limits in source resolution

Sažetak
Numerical simulation studies were performed using a multiple dipole source model and a spherical approximation of the head to examine how the resolution of simultaneously active neuromagnetic sources depends upon: 1) source modeling assumptions (i.e., number of assumed dipoles) ; 2) actual source parameters (e.g., location, orientation, and moment) ; and 3) measurement errors. Forward calculations were conducted for a series of source configurations in which the number of dipoles, specific dipole parameters, and noise levels were systematically varied. Simulated noisy field distributions were fit by multiple dipole models of increasing model order (1, 2, ..., 6 and alternative statistical approaches (i.e., percent of variance, reduced chi-square, and F-ratio) were compared for their effectiveness in determining adequate model order. Limits of spatial resolution were established for a variety of multi- source configurations and noise conditions. Implications for the analysis of empirical data are discussed.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Selma Supek (autor)

Poveznice na cjeloviti tekst rada:

doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Supek, Selma; Aine, Cheryl J.
Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution // IEEE transactions on biomedical engineering, 40 (1993), 6; 529-540 doi:10.1109/10.237672 (međunarodna recenzija, članak, znanstveni)
Supek, S. & Aine, C. (1993) Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution. IEEE transactions on biomedical engineering, 40 (6), 529-540 doi:10.1109/10.237672.
@article{article, author = {Supek, Selma and Aine, Cheryl J.}, year = {1993}, pages = {529-540}, DOI = {10.1109/10.237672}, keywords = {magnetoencefalography, spatio-temporal resolution, model order, statistical measures of goodness-of-fit, limits in source resolution}, journal = {IEEE transactions on biomedical engineering}, doi = {10.1109/10.237672}, volume = {40}, number = {6}, issn = {0018-9294}, title = {Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution}, keyword = {magnetoencefalography, spatio-temporal resolution, model order, statistical measures of goodness-of-fit, limits in source resolution} }
@article{article, author = {Supek, Selma and Aine, Cheryl J.}, year = {1993}, pages = {529-540}, DOI = {10.1109/10.237672}, keywords = {magnetoencefalography, spatio-temporal resolution, model order, statistical measures of goodness-of-fit, limits in source resolution}, journal = {IEEE transactions on biomedical engineering}, doi = {10.1109/10.237672}, volume = {40}, number = {6}, issn = {0018-9294}, title = {Simulation studies of multiple dipole neuromagnetic source localization : Model order and limits of source resolution}, keyword = {magnetoencefalography, spatio-temporal resolution, model order, statistical measures of goodness-of-fit, limits in source resolution} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • PubMed
  • Index medicus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font