Pregled bibliografske jedinice broj: 611055
Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from −70 ◦C to +20 ◦C
Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from −70 ◦C to +20 ◦C // International journal of thermophysics, 33 (2011), 8/9; 1451-1457 doi:10.1007/s10765-011-1105-9 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 611055 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from −70 ◦C to +20 ◦C
Autori
Heinonen, Martti ; Zvizdić, Davor ; Šestan, Danijel
Izvornik
International journal of thermophysics (0195-928X) 33
(2011), 8/9;
1451-1457
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
bilateral degrees of equivalence; Dew-point temperature; supplementary comparison
Sažetak
The first European humidity key comparison EURAMET-T.K6 was completed in 2008, and it covered the dew-point temperature range from −50 ◦C to +20 ◦C. Both LPM and MIKES participated in the comparison, but a new low dew-point generator was introduced at LPM as a result of progress in the EUROMET P912 project. To extend the range of available comparison evidence down to −70 ◦C and to study the validity of improved uncertainties of LPM, a bilateral comparison was carried out between LPM and MIKES in 2009–2010. The applied comparison procedure was similar to that applied in EURAMET-T.K6. However, only one transfer standard was used instead of two units and the measurement point −70 ◦C was added in the measurement scheme. The results show that the bilateral equivalence between LPM and MIKES is between (0.00±0.06) ◦C and (0.02±0.08) ◦C in the range from −50 ◦C to +20 ◦C and (0.01 ± 0.10) ◦C at −70 ◦C. Using MIKES results as the link to the EURAMET.T-K6, it is shown that the difference between the results obtained with the new LPM dew- point temperature standard and the EURAMET Comparison Reference Values is between (−0.02 ± 0.08) ◦C at 20◦C and (+0.02 ± 0.07) ◦C at −50 ◦C.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Projekti:
120-0000000-3322 - Razvoj nacionalnog etalona temperature (Zvizdić, Davor, MZOS ) ( CroRIS)
Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus