Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 610496

Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry


Siketić, Zdravko; Bogdanović Radović, Ivančica
Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry // Nuclear Instruments and Methods in Physics Research. Section B, 296 (2013), 78-81 doi:10.1016/j.nimb.2012.11.006 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 610496 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry

Autori
Siketić, Zdravko ; Bogdanović Radović, Ivančica

Izvornik
Nuclear Instruments and Methods in Physics Research. Section B (0168-583X) 296 (2013); 78-81

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
ORTEC SSB detector-F series; Heavy ions; Energy and mass resolution; TOF-ERDA

Sažetak
In the Elastic Recoil Detection Analysis (ERDA) and Heavy Ion Rutherford Backscattering Spectrometry (HIRBS), silicon surface barrier (SSB) detectors as well as other types of Si charged particle detectors are conventionally used for measuring ion energy due to their simplicity and ease of use. Energy resolution of such detectors is a limiting factor for both, mass and depth resolution in the experiment. In the present work we have studied performance of the commercially available F series ORTEC SSB detector designed in particular for heavy ion spectroscopy (BF-023-300-60). Detector energy and mass resolution were measured for a wide range of ion masses (7Li, 16O, 28Si, 35Cl and 81Br) and energies (2–20 MeV). Obtained results were compared with the already published data for a standard A series ORTEC SSB detector (BA-017-100-100) and gas ionization chambers. Possible application of the F series SSB detector in time-of-flight ERDA (TOF-ERDA) spectrometer was discussed.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
098-1191005-2876 - Procesi interakcije ionskih snopova i nanostrukture (Jakšić, Milko, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com ac.els-cdn.com dx.doi.org

Citiraj ovu publikaciju:

Siketić, Zdravko; Bogdanović Radović, Ivančica
Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry // Nuclear Instruments and Methods in Physics Research. Section B, 296 (2013), 78-81 doi:10.1016/j.nimb.2012.11.006 (međunarodna recenzija, članak, znanstveni)
Siketić, Z. & Bogdanović Radović, I. (2013) Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry. Nuclear Instruments and Methods in Physics Research. Section B, 296, 78-81 doi:10.1016/j.nimb.2012.11.006.
@article{article, author = {Siketi\'{c}, Zdravko and Bogdanovi\'{c} Radovi\'{c}, Ivan\v{c}ica}, year = {2013}, pages = {78-81}, DOI = {10.1016/j.nimb.2012.11.006}, keywords = {ORTEC SSB detector-F series, Heavy ions, Energy and mass resolution, TOF-ERDA}, journal = {Nuclear Instruments and Methods in Physics Research. Section B}, doi = {10.1016/j.nimb.2012.11.006}, volume = {296}, issn = {0168-583X}, title = {Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry}, keyword = {ORTEC SSB detector-F series, Heavy ions, Energy and mass resolution, TOF-ERDA} }
@article{article, author = {Siketi\'{c}, Zdravko and Bogdanovi\'{c} Radovi\'{c}, Ivan\v{c}ica}, year = {2013}, pages = {78-81}, DOI = {10.1016/j.nimb.2012.11.006}, keywords = {ORTEC SSB detector-F series, Heavy ions, Energy and mass resolution, TOF-ERDA}, journal = {Nuclear Instruments and Methods in Physics Research. Section B}, doi = {10.1016/j.nimb.2012.11.006}, volume = {296}, issn = {0168-583X}, title = {Energy resolution measurement and application of the F series ORTEC SSB detector in TOF-ERDA spectrometry}, keyword = {ORTEC SSB detector-F series, Heavy ions, Energy and mass resolution, TOF-ERDA} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • PsycLit (Psychological Abstracts)


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font