Pregled bibliografske jedinice broj: 607248
Nuclear microprobe analysis and imaging : Current state of the art performances
Nuclear microprobe analysis and imaging : Current state of the art performances // Nuclear instruments & methods in physics research. B, 136/138 (1998), 313-317 doi:10.1016/S0168-583X(97)00710-6 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 607248 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Nuclear microprobe analysis and imaging : Current state of the art performances
Autori
Watt, F. ; Osipowicz, T. ; Choo, T.F. ; Orlić, Ivica ; Tang, S.M.
Izvornik
Nuclear instruments & methods in physics research. B (0168-583X) 136/138
(1998);
313-317
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
proton beam; alpha particle beam; STIM; IBIC; PIXE
Sažetak
The current state-of-the-art performances claimed for nuclear microbeam spatial resolutions are: (a) 400 nm spot sizes for high current (100 pA) proton beams, (b) 400 nm for high current alpha particle beams, (c) 100 nm for low proton current (<0.1 pA) applications such as Scanning Transmission Ion Microscopy (STIM) and Ion Beam Induced Charge (IBIC) and (d) 50 nm for low current alpha particles. These claims, however, have been undermined not only by the lack of a common and generally accepted resolution standard, but also by the lack of a consistent approach between groups regarding a recognised method of beam spot measurement. The lack of a definitive method for assessing spatial resolution is hindering the future development of nuclear microprobes to higher spatial resolutions. We require the manufacture of resolution standards specifically tailored for nuclear microprobe spot size measurements, for both high and low current operations. Until such resolution standards are available, one commercially available standard which has high potential for high current proton beam resolution tests is the Ebeam test chip manufactured for the characterisation of electron beam testers. This chip has patterns as small as 0.5 lm in size produced in 0.5 lm thick aluminium by direct electron beam writing. Using both analytical Particle Induced X-ray Emission (PIXE) imaging and PIXE line scans, the nuclear microscope facility at the National University of Singapore has demonstrated spatial resolutions of less than 400 nm for a 100 pA beam of 2 MeV protons. Low current resolution standards have more stringent requirements. One potential standard tested in Singapore is a prototype self-supporting X-ray mask used in X-ray lithography. This test standard, however, is not commercially available at the moment, is fragile and therefore dicult to handle and easily fractured. Using o-axis STIM imaging and line scanning over this mask, the NUS nuclear microscope facility has demonstrated beam spot sizes less than 130 nm for a 1 pA 2 MeV proton beam.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
Napomena
Rad je prezentiran na skupu Ion Beam Analysis, održanom od 27.07.–01.08.1997., Lisabon, Portugal ; Maria Fernanda Da Silva, Jose Carvalho Soares, Mark Breese (ur.).
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus