Traditional column connections with iron dowels - experimental and numerical analysis


Atalić, Josip; Lazarević, Damir; Šavor, Marta
Traditional column connections with iron dowels - experimental and numerical analysis // Proceedings of the International Conference on Structural Analysis of Historical Constructions, SAHC 2012 / Jerzy Jasienko (ur.).
Wrocław: Dolnoslaskie Wydawnictwo Edukacyjne, 2012. str. 619-627 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 606318 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Traditional column connections with iron dowels - experimental and numerical analysis

Autori
Atalić, Josip ; Lazarević, Damir ; Šavor, Marta

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the International Conference on Structural Analysis of Historical Constructions, SAHC 2012 / Jerzy Jasienko - Wrocław : Dolnoslaskie Wydawnictwo Edukacyjne, 2012, 619-627

ISBN
978-83-7125-216-7

Skup
International Conference on Structural Analysis of Historical Constructions, SAHC 2012

Mjesto i datum
Wrocław, Poljska, 15.10.2012. - 17.10.2012

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Laboratory tests; Numerical analysis; Stone column; Capital; Base; Iron dowel; Rotational stiffness; Contact stress; Eccentric load; Irregularities of contacts areas; Fracture propagation

Sažetak
Permanent problems with stone columns in Croatia motivated us on comprehensive research. Retrofit of columns, being noted for centuries and existing distinct fractures concentrated around connections with capitals and bases point to some fundamental deficiency of the structural system. Traditional connections consist of carefully smoothed contact areas joined only with centrally placed iron dowel what makes them very sensitive to any disturbance from vertical position. Analyses show that even a small imperfection in the construction process, temperature changes and especially eccentric loads result in the leaning of the contact to one side. Described contacts do not have sufficient rotational stiffness to compensate rotations. Eventually, high edge stresses cause numerous fractures. Performed laboratory tests pointed out additional problem of irregularities of contact areas, which, together with eccentric load, became critical for all specimens. Tests were carried out on almost real scale samples from traditional quarries. Testing procedure ensured separate analyses to centric and eccentric loading with respect to actual stress distribution in structures. All abovementioned assertions were confirmed with a range of numerical models: from simple frame and shell models to complex solid models. All models were calibrated with results of the laboratory tests. This work shows that it is essential to understand real nature of connections behaviour if we want to approximate real stress distributions, positions of thrust lines and finally safety factor in order to form adequate retrofit strategies.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Projekti:
082-1201829-2166 - Nestandardni modeli građevinskih konstrukcija (Lazarević, Damir, MZOS ) ( CroRIS)

Ustanove:
Građevinski fakultet, Zagreb

Profili:

Avatar Url Damir Lazarević (autor)

Avatar Url Josip Atalić (autor)

Avatar Url Marta Šavor Novak (autor)


Citiraj ovu publikaciju:

Atalić, Josip; Lazarević, Damir; Šavor, Marta
Traditional column connections with iron dowels - experimental and numerical analysis // Proceedings of the International Conference on Structural Analysis of Historical Constructions, SAHC 2012 / Jerzy Jasienko (ur.).
Wrocław: Dolnoslaskie Wydawnictwo Edukacyjne, 2012. str. 619-627 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Atalić, J., Lazarević, D. & Šavor, M. (2012) Traditional column connections with iron dowels - experimental and numerical analysis. U: Jerzy Jasienko (ur.)Proceedings of the International Conference on Structural Analysis of Historical Constructions, SAHC 2012.
@article{article, author = {Atali\'{c}, Josip and Lazarevi\'{c}, Damir and \v{S}avor, Marta}, year = {2012}, pages = {619-627}, keywords = {Laboratory tests, Numerical analysis, Stone column, Capital, Base, Iron dowel, Rotational stiffness, Contact stress, Eccentric load, Irregularities of contacts areas, Fracture propagation}, isbn = {978-83-7125-216-7}, title = {Traditional column connections with iron dowels - experimental and numerical analysis}, keyword = {Laboratory tests, Numerical analysis, Stone column, Capital, Base, Iron dowel, Rotational stiffness, Contact stress, Eccentric load, Irregularities of contacts areas, Fracture propagation}, publisher = {Dolnoslaskie Wydawnictwo Edukacyjne}, publisherplace = {Wroc\law, Poljska} }
@article{article, author = {Atali\'{c}, Josip and Lazarevi\'{c}, Damir and \v{S}avor, Marta}, year = {2012}, pages = {619-627}, keywords = {Laboratory tests, Numerical analysis, Stone column, Capital, Base, Iron dowel, Rotational stiffness, Contact stress, Eccentric load, Irregularities of contacts areas, Fracture propagation}, isbn = {978-83-7125-216-7}, title = {Traditional column connections with iron dowels - experimental and numerical analysis}, keyword = {Laboratory tests, Numerical analysis, Stone column, Capital, Base, Iron dowel, Rotational stiffness, Contact stress, Eccentric load, Irregularities of contacts areas, Fracture propagation}, publisher = {Dolnoslaskie Wydawnictwo Edukacyjne}, publisherplace = {Wroc\law, Poljska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font