Pregled bibliografske jedinice broj: 6010
Energy conservation using a recuperative drying process
Energy conservation using a recuperative drying process // Energy conversion and management, 37 (1996), 9; 1393-1399 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 6010 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Energy conservation using a recuperative drying process
Autori
Budin, Rajka ; Mihelić-Bogdanić, Alka ; Filipan, Veljko
Izvornik
Energy conversion and management (0196-8904) 37
(1996), 9;
1393-1399
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
drying; recuperation; energy savings
Sažetak
Having analyzed one stage and two stage recuperative drying it was established that the heat economy with the two stage process is approximately twice as good. Compared with the process without heat recovery, the energy savings for the ventilation heater is 41% and for the ventilation and supply air heaters is about 60%.
Izvorni jezik
Engleski
Znanstvena područja
Kemijsko inženjerstvo
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Scopus