Performance of the StatStrip POCT analyzer in detecting hypoglycaemic episodes in diabetic patients
Performance of the StatStrip POCT analyzer in detecting hypoglycaemic episodes in diabetic patients // Biochemia Medica / Šimundić, Ana-Maria (ur.).
Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM), 2012. str. A84-A84 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 598187 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Performance of the StatStrip POCT analyzer in detecting hypoglycaemic episodes in diabetic patients
Autori
Vučić Lovrenčić, Marijana ; Radišić Biljak, Vanja ; Božičević, Sandra ; Car, Nikica
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Biochemia Medica
/ Šimundić, Ana-Maria - Zagreb : Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM), 2012, A84-A84
Skup
2nd European Joint Congress of EFLM and UEMS and 7th Congress of the Croatian Society for Medical Biochemistry and Laboratory medicine (CSMBLM): Laboratory Medicine at the Clinical Interface.
Mjesto i datum
Dubrovnik, Hrvatska, 10.10.2012. - 13.10.2012
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Hypoglycaemia; diabetes; StatStrip; POCT
Sažetak
Background: Improving glycaemic control, whilst minimizing risk of hypoglycaemia is the ultimate goal of diabetes management. Intensified insulin treatment is the most common source of iatrogenic hypoglycaemia. Due to the hypoglycaemia unawareness, common in diabetes, many of the hypoglycaemic episodes remain undiagnosed and untreated, leading to a variety of adverse outcomes, ranging from mild autonomic symptoms to death. Accurate and readily available plasma glucose monitoring is of utmost importance in diagnosis and subsequent treatment of hypoglycaemia. The aim of this study was to evaluate the performance of a new type glucose sensor for the POCT glucose analyzer (StatStrip, Nova Biomedical, USA) in detecting hypoglycaemic episodes in diabetic patients upon institution of intensified insulin treatment. Materials and methods: Capillary plasma glucose was measured by the StatStrip POCT glucose analyzer in hospitalized diabetic patients (N = 49) upon institution of intensified insulin treatment (glycaemic profile: 8 times per 24 hours) and results were compared to the reference hexokinase procedure (Olympus AU400, Beckman Coulter, USA). Results: A total of 41 hypoglycaemic episodes (plasma glucose ≤ 3.9 mmol/L) were detected in the study period. There was no statistically significant bias between plasma glucose, as measured by the StatStrip and reference procedure (3.0 ± 0.83 vs. 3.1 ± 0.69 mmol/L, P = 0.071). Diagnostic test revealed a 95.1% sensitivity of the StatStrip in detecting hypoglycaemia, when tested against reference procedure. Conclusions: The StatStrip POCT glucose analyzer showed excellent performance and clinical accuracy for detecting hypoglycaemic episodes in diabetic patients treated with intensified insulin therapy.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinička bolnica "Merkur",
Klinika za dijabetes, endokrinologiju i bolesti metabolizma Vuk Vrhovac
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE