Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 595688

Testing of confined masonry walls with different connection details


Sigmund, Vladimir; Matošević, Djurdjica
Testing of confined masonry walls with different connection details // 15th World Conference on Earthquake Engineering / IAEE (ur.).
Lisabon: International Association for Earthquake Engineering, 2012. str. WCEE2012_2277-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 595688 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Testing of confined masonry walls with different connection details

Autori
Sigmund, Vladimir ; Matošević, Djurdjica

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
15th World Conference on Earthquake Engineering / IAEE - Lisabon : International Association for Earthquake Engineering, 2012, WCEE2012_2277-1

Skup
15th World Conference on Earthquake Engineering

Mjesto i datum
Lisabon, Portugal, 24.09.2012. - 28.09.2012

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
confined masonry; connection details; seismis design

Sažetak
According to the Eurocodes horizontal and vertical confining elements should be bonded together and anchored to masonry by manner of construction (toothing) or by mechanical connectors (dowels). Both methods cause problems during construction and it is a common practice, at least in Eastern Europe, in trying to avoid them. The authors studied the influence of three different types of connection details between the masonry panel and r/c tie-columns on the resistance and displacement capacity of confined masonry walls within a scope of the Croatian project "Seismic design of infilled frames". Confining elements around the masonry wall increased stiffness and lateral load capacity. Connection among the masonry wall and ties increased ductile behaviour of the confined masonry. Existing equations for calculation of the lateral strength in EC6 are either under- or over estimating the observed values.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Projekti:
149-1492966-1536 - Seizmički proračun okvirnih konstrukcija s ispunom (Sigmund, Vladimir, MZOS ) ( CroRIS)

Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Vladimir Sigmund (autor)

Avatar Url Đurđica Matošević (autor)


Citiraj ovu publikaciju:

Sigmund, Vladimir; Matošević, Djurdjica
Testing of confined masonry walls with different connection details // 15th World Conference on Earthquake Engineering / IAEE (ur.).
Lisabon: International Association for Earthquake Engineering, 2012. str. WCEE2012_2277-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Sigmund, V. & Matošević, D. (2012) Testing of confined masonry walls with different connection details. U: IAEE (ur.)15th World Conference on Earthquake Engineering.
@article{article, author = {Sigmund, Vladimir and Mato\v{s}evi\'{c}, Djurdjica}, year = {2012}, pages = {WCEE2012\_2277-1-WCEE2012\_2277-8}, keywords = {confined masonry, connection details, seismis design}, title = {Testing of confined masonry walls with different connection details}, keyword = {confined masonry, connection details, seismis design}, publisher = {International Association for Earthquake Engineering}, publisherplace = {Lisabon, Portugal} }
@article{article, author = {Sigmund, Vladimir and Mato\v{s}evi\'{c}, Djurdjica}, year = {2012}, pages = {WCEE2012\_2277-1-WCEE2012\_2277-8}, keywords = {confined masonry, connection details, seismis design}, title = {Testing of confined masonry walls with different connection details}, keyword = {confined masonry, connection details, seismis design}, publisher = {International Association for Earthquake Engineering}, publisherplace = {Lisabon, Portugal} }




Contrast
Increase Font
Decrease Font
Dyslexic Font