Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 588079

Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor


Zeqiri, Bajram; Žauhar, Gordana; Rajagopal, Srinath; Pounder, Adam
Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor // Metrologia, 49 (2012), 3; 368-381 doi:10.1088/0026-1394/49/3/368 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 588079 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor

Autori
Zeqiri, Bajram ; Žauhar, Gordana ; Rajagopal, Srinath ; Pounder, Adam

Izvornik
Metrologia (0026-1394) 49 (2012), 3; 368-381

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
ultrasound; output power measurement; pyroelectric; diagnostic ultrasound

Sažetak
A systematic study of the application of a novel pyroelectric technique to the measurement of diagnostic-level medical ultrasound output power is described. The method exploits the pyroelectric properties of a 0.028 mm thick membrane of polyvinylidene fluoride (PVDF), backed by an acoustic absorber whose ultrasonic absorption coefficient approaches 1000 dB cm−1 at 3 MHz. When exposed to an ultrasonic field, absorption of ultrasound adjacent to the PVDF–absorber interface results in heating and the generation of a pyroelectric output voltage across gold electrodes deposited on the membrane. For a sensor large enough to intercept the whole of the acoustic beam, the output voltage can be calibrated for the measurement of acoustic output power. A number of key performance properties of the method have been investigated. The technique is very sensitive, with a power to voltage conversion factor of typically 0.23 V W−1. The frequency response of a particular embodiment of the sensor in which acoustic power reflected at the absorber–PVDF interface is subsequently returned to the pyroelectric membrane to be absorbed, has been evaluated over the frequency range 1.5 MHz to 10 MHz. This has shown the frequency response to be flat to within ±4%, above 2.5 MHz. Below this frequency, the sensitivity falls by 20% at 1.5 MHz. Linearity of the technique has been demonstrated to within ±1.6% for applied acoustic power levels from 1 mW up to 120 mW. A number of other studies targeted at assessing the achievable measurement uncertainties are presented. These involve: the effects of soaking, the influence of the angle of incidence of the acoustic beam, measurement repeatability and sensitivity to transducer positioning. Additionally, over the range 20 °C to 30 °C, the rate of change in sensitivity with ambient temperature has been shown to be +0.5% °C−1. Implications of the work for the development of a sensitive, traceable, portable, secondary method of ultrasound output power measurement, appropriate for clinical diagnostic ultrasound systems, are discussed.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka

Profili:

Avatar Url Gordana Žauhar (autor)

Poveznice na cjeloviti tekst rada:

doi iopscience.iop.org

Citiraj ovu publikaciju:

Zeqiri, Bajram; Žauhar, Gordana; Rajagopal, Srinath; Pounder, Adam
Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor // Metrologia, 49 (2012), 3; 368-381 doi:10.1088/0026-1394/49/3/368 (međunarodna recenzija, članak, znanstveni)
Zeqiri, B., Žauhar, G., Rajagopal, S. & Pounder, A. (2012) Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor. Metrologia, 49 (3), 368-381 doi:10.1088/0026-1394/49/3/368.
@article{article, author = {Zeqiri, Bajram and \v{Z}auhar, Gordana and Rajagopal, Srinath and Pounder, Adam}, year = {2012}, pages = {368-381}, DOI = {10.1088/0026-1394/49/3/368}, keywords = {ultrasound, output power measurement, pyroelectric, diagnostic ultrasound}, journal = {Metrologia}, doi = {10.1088/0026-1394/49/3/368}, volume = {49}, number = {3}, issn = {0026-1394}, title = {Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor}, keyword = {ultrasound, output power measurement, pyroelectric, diagnostic ultrasound} }
@article{article, author = {Zeqiri, Bajram and \v{Z}auhar, Gordana and Rajagopal, Srinath and Pounder, Adam}, year = {2012}, pages = {368-381}, DOI = {10.1088/0026-1394/49/3/368}, keywords = {ultrasound, output power measurement, pyroelectric, diagnostic ultrasound}, journal = {Metrologia}, doi = {10.1088/0026-1394/49/3/368}, volume = {49}, number = {3}, issn = {0026-1394}, title = {Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor}, keyword = {ultrasound, output power measurement, pyroelectric, diagnostic ultrasound} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • Compendex (EI Village)
  • GeoRef
  • MathSciNet


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font