Testing of Measuring Frequency of Electro-Optical Distance Meters


Barković, Đuro; Zrinjski, Mladen; Peša, Martina
Testing of Measuring Frequency of Electro-Optical Distance Meters // Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012 / International Multidisciplinary Scientific GeoConference SGEM (ur.).
Sofija: International Multidisciplinary Scientific GeoConferences (SGEM), 2012. str. 805-812 (ostalo, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 584200 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Testing of Measuring Frequency of Electro-Optical Distance Meters

Autori
Barković, Đuro ; Zrinjski, Mladen ; Peša, Martina

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012 / International Multidisciplinary Scientific GeoConference SGEM - Sofija : International Multidisciplinary Scientific GeoConferences (SGEM), 2012, 805-812

Skup
12th International Multidisciplinary Scientific GeoConference SGEM 2012

Mjesto i datum
Albena, Bugarska, 17.06.2012. - 23.06.2012

Vrsta sudjelovanja
Ostalo

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
measuring frequency; electro-optical distance meter; air temperature; multiplication constant

Sažetak
The multiplication constant of electro-optical distance meters is changed as a result of quartz crystals aging in the distance meter oscillator. Other parts are also aging, the misalignment of instruments occurs during the transportation, along with the deformation caused by the temperature changes. It is therefore necessary to measure the measuring frequency in distance meters regularly. The measuring frequency of distance meters is tested in the laboratory conditions by means of frequency counter that needs to be calibrated previously. A new method of automated frequency counter calibrations by means of GPS signal has been developed in the Laboratory for Measurements and Measuring Technique at the Faculty of Geodesy, University of Zagreb. The paper describes the system for automated measurement of frequency in the electro-optical distance meters Leica TC1800 and Leica TCA2003. The measurements were performed in the Laboratory for Measurements and Measuring Technique at the Faculty of Geodesy, University of Zagreb at three temperatures, approximately: 13 °C, 20 °C and 31 °C. There is also the manner of recording the measuring data presented that is performed by means of the software Agilent IntuiLink Counter version 1.0. At the end, the data obtained from testing of the measuring frequency in the electro-optical distance meters TC1800 and Leica TCA2003 are presented graphically.

Izvorni jezik
Engleski

Znanstvena područja
Geodezija



POVEZANOST RADA


Projekti:
007-0072284-2287 - Geopotencijal i geodinamika Jadrana (Geo++Adria) (Bašić, Tomislav, MZOS ) ( CroRIS)
007-1201785-3539 - Razvoj znanstvenog mjeriteljskog laboratorija za geodetske instrumente (Solarić, Nikola, MZOS ) ( CroRIS)

Ustanove:
Geodetski fakultet, Zagreb

Profili:

Avatar Url Mladen Zrinjski (autor)

Avatar Url Đuro Barković (autor)


Citiraj ovu publikaciju:

Barković, Đuro; Zrinjski, Mladen; Peša, Martina
Testing of Measuring Frequency of Electro-Optical Distance Meters // Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012 / International Multidisciplinary Scientific GeoConference SGEM (ur.).
Sofija: International Multidisciplinary Scientific GeoConferences (SGEM), 2012. str. 805-812 (ostalo, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Barković, Đ., Zrinjski, M. & Peša, M. (2012) Testing of Measuring Frequency of Electro-Optical Distance Meters. U: International Multidisciplinary Scientific GeoConference SGEM (ur.)Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012.
@article{article, author = {Barkovi\'{c}, \DJuro and Zrinjski, Mladen and Pe\v{s}a, Martina}, year = {2012}, pages = {805-812}, keywords = {measuring frequency, electro-optical distance meter, air temperature, multiplication constant}, title = {Testing of Measuring Frequency of Electro-Optical Distance Meters}, keyword = {measuring frequency, electro-optical distance meter, air temperature, multiplication constant}, publisher = {International Multidisciplinary Scientific GeoConferences (SGEM)}, publisherplace = {Albena, Bugarska} }
@article{article, author = {Barkovi\'{c}, \DJuro and Zrinjski, Mladen and Pe\v{s}a, Martina}, year = {2012}, pages = {805-812}, keywords = {measuring frequency, electro-optical distance meter, air temperature, multiplication constant}, title = {Testing of Measuring Frequency of Electro-Optical Distance Meters}, keyword = {measuring frequency, electro-optical distance meter, air temperature, multiplication constant}, publisher = {International Multidisciplinary Scientific GeoConferences (SGEM)}, publisherplace = {Albena, Bugarska} }