Pregled bibliografske jedinice broj: 584072
Effect of borehole array geometry and thermal interferences on geothermal heat pump system
Effect of borehole array geometry and thermal interferences on geothermal heat pump system // Energy conversion and management, 60 (2012), 134-142 doi:10.1016/j.enconman.2012.02.012 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 584072 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Effect of borehole array geometry and thermal interferences on geothermal heat pump system
Autori
Kurevija, Tomislav ; Vulin, Domagoj ; Krapec, Vedrana
Izvornik
Energy conversion and management (0196-8904) 60
(2012);
134-142
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
geothermal heat pumps; modeling of borehole array geometry; thermal interferences; thermogeology
Sažetak
Properly sized borehole heat exchanger in geothermal heat pump system (widely known also as ground source heat pump system) needs to minimize long-term ground and working fluid temperature changes. These changes occur due to imbalances of heat extracted from the ground during winter and heat rejected into the ground during summer months, as well as thermal interferences of adjacent boreholes in borehole array. Simple calculations and spreadsheet-based analogical solutions of required borehole length for heat transfer run into difficulties when dealing with such large, complex ground source heat pump heating and cooling systems which use compact borehole array. A number of analytical computer programs are available to simulate how ground loop fluid temperature varies in such complex systems, using so-called ‘g-function’ – a mathematical function dependent on the geometry and shape of the borehole array. The type of calculation involves a type of ‘step-function’, where 24 h ‘step’ of peak loading is superimposed on a top of a long-term base load. In analytical simulation models, the base load is typically specified as the heating and cooling load per month of a typical year, and is simulated as the combination of sequential monthly steps. This paper will show, by simulating long-term operation of complex geothermal heat pump system with multiple boreholes in various geometric arrays, how spacing of adjacent boreholes and thermal interferences influence required borehole length for heat transfer.
Izvorni jezik
Engleski
Znanstvena područja
Geologija, Rudarstvo, nafta i geološko inženjerstvo
POVEZANOST RADA
Projekti:
195-1951322-1340 - Zbrinjavanje ugljikovog dioksida iz geotermalnih i ugljikovodičnih ležišta (Golub, Miroslav, MZOS ) ( CroRIS)
195-1951390-1398 - Racionalno korištenje energetskih mineralnih sirovina u Hrvatskoj (Rajković, Damir, MZOS ) ( CroRIS)
Ustanove:
Rudarsko-geološko-naftni fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus