Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 579297

Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology


Herceg, Zoran; Juraga, Edita; Sobota-Šalamon, Brankica; Režek Jambrak, Anet
Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology // Czech journal of food sciences, 30 (2012), 2; 108-118 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 579297 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology

Autori
Herceg, Zoran ; Juraga, Edita ; Sobota-Šalamon, Brankica ; Režek Jambrak, Anet

Izvornik
Czech journal of food sciences (1212-1800) 30 (2012), 2; 108-118

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
high power ultrasound; total mesophilic bacteria count; D values

Sažetak
High-intensity ultrasound was used to investigate the inactivation of microorganisms in raw bovine milk. Raw bovine milk with 4% of milk fat was treated with ultrasonic probe that was 12 mm in diameter and with 20 kHz frequency immerged in milk directly. In the ultrasound treatment, three parameters were varied according to the statistical experimental design. The centre composite design was used to design and optimise the experimental parameters: temperature (20, 40, and 60 °C), amplitude (120, 90, and 60 µm), and time (6, 9, and 12 min). All analyses were performed immediately after sonication and after 3 days and 5 days of storage under refrigeration at 4°C. The factors that seem to affect substantially the inactivation of microorganisms in using ultrasound are the amplitude of the ultrasonic waves, the exposure/contact time with the microorganisms, and the temperature of the treatment. The results achieved indicate a significant inactivation of microorganisms under longer periods of the treatment with ultrasonic probe, particularly in combination of higher temperature and amplitude. The output optimal value of total bacteria count was defined by Statgraphics where the lowest bacteria count was 3.688 log CFU/ml for the following specific ultrasound parameters: amplitude 120 µm, treatment time 9.84 min, and temperature 45.34°C.

Izvorni jezik
Engleski

Znanstvena područja
Prehrambena tehnologija



POVEZANOST RADA


Projekti:
058-0580696-2533 - Nove tehnike procesiranja u proizvodnji funkcionalne hrane (Lelas, Vesna, MZOS ) ( CroRIS)

Ustanove:
Prehrambeno-biotehnološki fakultet, Zagreb

Profili:

Avatar Url Anet Režek Jambrak (autor)

Avatar Url Zoran Herceg (autor)

Citiraj ovu publikaciju:

Herceg, Zoran; Juraga, Edita; Sobota-Šalamon, Brankica; Režek Jambrak, Anet
Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology // Czech journal of food sciences, 30 (2012), 2; 108-118 (međunarodna recenzija, članak, znanstveni)
Herceg, Z., Juraga, E., Sobota-Šalamon, B. & Režek Jambrak, A. (2012) Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology. Czech journal of food sciences, 30 (2), 108-118.
@article{article, author = {Herceg, Zoran and Juraga, Edita and Sobota-\v{S}alamon, Brankica and Re\v{z}ek Jambrak, Anet}, year = {2012}, pages = {108-118}, keywords = {high power ultrasound, total mesophilic bacteria count, D values}, journal = {Czech journal of food sciences}, volume = {30}, number = {2}, issn = {1212-1800}, title = {Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology}, keyword = {high power ultrasound, total mesophilic bacteria count, D values} }
@article{article, author = {Herceg, Zoran and Juraga, Edita and Sobota-\v{S}alamon, Brankica and Re\v{z}ek Jambrak, Anet}, year = {2012}, pages = {108-118}, keywords = {high power ultrasound, total mesophilic bacteria count, D values}, journal = {Czech journal of food sciences}, volume = {30}, number = {2}, issn = {1212-1800}, title = {Inactivation of mesophilic bacteria in milk by means of high intensity ultrasound using response surface methodology}, keyword = {high power ultrasound, total mesophilic bacteria count, D values} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font