Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 574945

ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion


Juranović Cindrić, Iva; Zeiner, Michaela; Krpetić, Martina; Stingeder, Gerhard
ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion // Microchemical journal, 105 (2012), 72-76 doi:10.1016/j.microc.2012.03.011 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 574945 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion

Autori
Juranović Cindrić, Iva ; Zeiner, Michaela ; Krpetić, Martina ; Stingeder, Gerhard

Izvornik
Microchemical journal (0026-265X) 105 (2012); 72-76

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
ICP-AES; microwave assisted digestion; minor and major elements; Cornelian cherry; Cornus mas L.

Sažetak
Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for the determination of minor and major elements present in Cornelian cherry (Cornus mas L.), as this fruit and its preservatives may be considered as important nutritional supplements. Prior to ICP-AES measurement, the samples were digested in a microwave assisted digestion system. The ICP-AES method was validated and optimized for the determination of selected elements in Cornelian cherry. The accuracy of the method as estimated through by spiking experiments was satisfactory, the recoveries obtained after microwave digestions in whole fruit (A), mesocarp (B) seed (C), and juice ranged from 84-123%, 74-115% 82-124%, and from 83-116% respectively. For microwave assisted digested Cornelian cherry samples of whole fruit (A), mesocarp (B) and seeds (C) the following limits of detection were obtained < 2 ng g-1 for Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Zn, Mg, and K, moderate 2-10 ng g-1 for B, and Ca. The highest LODs were obtained only for Al in mesocarp (B) and seeds (C) compared with whole fruit (A). For microwave assisted digested Cornelian cherry juice the limits of detection were in a range 0.04-0.108 µg/L. The precision of the method was evaluated using the standard deviation, RSD, of repeated determinations of the analytes and for all elements RSD ranged from 0.5 to 7% except for Na 12%. The intermediate precision (< 4.8%), the day-to-day reproducibility (< 6.8%), and the overall uncertainty of measurement (approx. 4-10%) for all elements analyzed demonstrated the good applicability of the chosen microwave assisted digestion procedure. Regarding potentially toxic elements, Cu and Pb are below 4 µg/g in the whole berry, Cr and Cd were not even detected.The order of magnitude of the concentrations for the elements found in whole fruit (whole fruit, A) and seed (C) are found to be similar for most of the elements of interest, namely in µg/g: 2.52 and 6.0 B, 2074.4 and 3971.8 Ca, 2.4 and 2.4 Cu, 7.8 and 4.1 Fe, 4019 and 3288 K, 288 and 237 Mg, 1.65 and 3.1 Mn, 22.9 and 41 Na, 9.0 and 6.9 Ni, 2.9 and 3.3 Pb, 6.9 and 12.5 Sr, respectively. In Cornelian cherry juice the content of Al, Ba, Cd, Cr, Cu, Mn, Pb, and Sr were below the limits of detection (0.06, 0.07, 0.07, 0.006, 0.01, 0.042, 0.056, 0.04 and 0.009 µg/L, respectively). The content of minor elements was 0.135 Fe, 0.163 Ni, 0.828 Zn and 1.47 mg/L B. The concentrations of major elements were 11.3 Na, 51.7 Ca, 94.3 Mg and 1326 mg/L K.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
119-1191342-1083 - Interakcije i dizajn bioaktivnih molekula (Novak, Predrag, MZOS ) ( CroRIS)

Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Iva Juranović Cindrić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com dx.doi.org

Citiraj ovu publikaciju:

Juranović Cindrić, Iva; Zeiner, Michaela; Krpetić, Martina; Stingeder, Gerhard
ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion // Microchemical journal, 105 (2012), 72-76 doi:10.1016/j.microc.2012.03.011 (međunarodna recenzija, članak, znanstveni)
Juranović Cindrić, I., Zeiner, M., Krpetić, M. & Stingeder, G. (2012) ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion. Microchemical journal, 105, 72-76 doi:10.1016/j.microc.2012.03.011.
@article{article, author = {Juranovi\'{c} Cindri\'{c}, Iva and Zeiner, Michaela and Krpeti\'{c}, Martina and Stingeder, Gerhard}, year = {2012}, pages = {72-76}, DOI = {10.1016/j.microc.2012.03.011}, keywords = {ICP-AES, microwave assisted digestion, minor and major elements, Cornelian cherry, Cornus mas L.}, journal = {Microchemical journal}, doi = {10.1016/j.microc.2012.03.011}, volume = {105}, issn = {0026-265X}, title = {ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion}, keyword = {ICP-AES, microwave assisted digestion, minor and major elements, Cornelian cherry, Cornus mas L.} }
@article{article, author = {Juranovi\'{c} Cindri\'{c}, Iva and Zeiner, Michaela and Krpeti\'{c}, Martina and Stingeder, Gerhard}, year = {2012}, pages = {72-76}, DOI = {10.1016/j.microc.2012.03.011}, keywords = {ICP-AES, microwave assisted digestion, minor and major elements, Cornelian cherry, Cornus mas L.}, journal = {Microchemical journal}, doi = {10.1016/j.microc.2012.03.011}, volume = {105}, issn = {0026-265X}, title = {ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas l.) after microwave assisted digestion}, keyword = {ICP-AES, microwave assisted digestion, minor and major elements, Cornelian cherry, Cornus mas L.} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font