Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 56840

Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields


Modlic, Borivoj; Malarić, Krešimir; Regvart, Boris; Bartolić, Juraj; Kviz, Boris
Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields // TELESCON 2000 Proceedings / nomen nescio (ur.).
Dresden: VDE VERLAG, 2000. str. 333-337 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 56840 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields

Autori
Modlic, Borivoj ; Malarić, Krešimir ; Regvart, Boris ; Bartolić, Juraj ; Kviz, Boris

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
TELESCON 2000 Proceedings / Nomen nescio - Dresden : VDE VERLAG, 2000, 333-337

Skup
The Third International Telecommunications Energy Special Conference

Mjesto i datum
Dresden, Njemačka, 07.05.2000. - 10.05.2000

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Power Amplifier; Electromagnetic Fields; RFI

Sažetak
The modern telecommunications facilities depend on power units, which can be shut down suddenly by severe disturbances. A large number of disturbances can be attributed to radiated electromagnetic emissions. Emission testing has been relatively easy. The immunity of electronic equipment to RFI is expressed as maximum electric field strength that it can withstand. The paper describes the respective test set-up. Besides standard measuring equipment like RF generator and a power amplifier, a cell is needed in which well defined electromagnetic field is established The cell was used to test a DC/DC converter. The paper exhibits the test procedure.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036015
036018
036028

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Boris Regvart (autor)

Avatar Url Borivoj Modlic (autor)

Avatar Url Krešimir Malarić (autor)

Avatar Url Boris Kviz (autor)

Avatar Url Juraj Bartolić (autor)


Citiraj ovu publikaciju:

Modlic, Borivoj; Malarić, Krešimir; Regvart, Boris; Bartolić, Juraj; Kviz, Boris
Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields // TELESCON 2000 Proceedings / nomen nescio (ur.).
Dresden: VDE VERLAG, 2000. str. 333-337 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Modlic, B., Malarić, K., Regvart, B., Bartolić, J. & Kviz, B. (2000) Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields. U: nomen nescio (ur.)TELESCON 2000 Proceedings.
@article{article, author = {Modlic, Borivoj and Malari\'{c}, Kre\v{s}imir and Regvart, Boris and Bartoli\'{c}, Juraj and Kviz, Boris}, year = {2000}, pages = {333-337}, keywords = {Power Amplifier, Electromagnetic Fields, RFI}, title = {Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields}, keyword = {Power Amplifier, Electromagnetic Fields, RFI}, publisher = {VDE VERLAG}, publisherplace = {Dresden, Njema\v{c}ka} }
@article{article, author = {Modlic, Borivoj and Malari\'{c}, Kre\v{s}imir and Regvart, Boris and Bartoli\'{c}, Juraj and Kviz, Boris}, year = {2000}, pages = {333-337}, keywords = {Power Amplifier, Electromagnetic Fields, RFI}, title = {Set-up for Testing Telecom Power Unit Immunity to Electromagnetic Fields}, keyword = {Power Amplifier, Electromagnetic Fields, RFI}, publisher = {VDE VERLAG}, publisherplace = {Dresden, Njema\v{c}ka} }