Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 552884

Applicability of the recommended reference intervals for serum creatinine concentrations


Flegar-Meštrić, Zlata; Perkov, Sonja; Kardum Paro, Mirjana Mariana; Sikirica , Mirjana; Ožvald, Ivan; Šimonović, Barbara; Šurina, Branka
Applicability of the recommended reference intervals for serum creatinine concentrations // 18th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine, Innsbruck, Austria, June 7-11, 2009:W-A178. Clin Chem Lab Med 2009 ; 47, Special Suppl., S305.
Innsbruck: Walter de Gruyter, 2009. (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 552884 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Applicability of the recommended reference intervals for serum creatinine concentrations

Autori
Flegar-Meštrić, Zlata ; Perkov, Sonja ; Kardum Paro, Mirjana Mariana ; Sikirica , Mirjana ; Ožvald, Ivan ; Šimonović, Barbara ; Šurina, Branka

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
18th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine, Innsbruck, Austria, June 7-11, 2009:W-A178. Clin Chem Lab Med 2009 ; 47, Special Suppl., S305. / - Innsbruck : Walter de Gruyter, 2009

Skup
Euromedlab Innsbruck 2009 ; 18th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine

Mjesto i datum
Innsbruck, Austrija, 07.06.2009. - 11.06.2009

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
calibration traceability; serum creatinie concentrations; enzymatic method

Sažetak
Background. Due to the recent international requirement for accurate and specific diagnostic tests and implementation of calibration traceability to high-order reference measurement procedures and reference materials the aim of this study was to validate the applicability of the recommended “common” reference intervals for serum creatinine concentrations using specific enzymatic method to the Croatian population. Methods. The reference group comprised 120 males and 120 females aged between 18-74 years who were “a priori” selected in accordance with the approach proposed by the CLSI C28 document. Sera were frozen at -80 ºC until analyses. The Creatinine Enzymatic assay (Olympus OSR61204) standardized against IDMS method and Creatinine Jaffe Kinetic method (Olympus OSR6178) were used. Results. Method comparison between Creatinine Enzymatic (X) and Jaffe kinetic method (y) gave the following P/B equation for the whole group (n=240): y=1.00x +17.00 ; r=0.968. The obtained deviation between the specific und unspecific creatinine assays was in accordance with the previous publications. The reference intervals (central 95th percentiles) obtained with Creatinine Enzymatic assay ranged from 54 to 107 µmol/L for males and from 50 to 93 µmol/L for females vs. IFCC recommended reference intervals: 64 - 104 and 49 - 90 µmol/L for males and females, respectively. Conclusions. The comparability of the obtained results confirmed the applicability of the recently recommended “common” reference intervals by the IFCC Committee on Reference Intervals to the Croatian population for all laboratories measuring serum creatinie concentrations by enzymatic method traceable to the high-order reference measurement procedures.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
108-1081873-1893 - Prognostički faktori, dijagnostika i terapija hemoblastoza (Jakšić, Branimir, MZOS ) ( CroRIS)

Ustanove:
Klinička bolnica "Merkur"


Citiraj ovu publikaciju:

Flegar-Meštrić, Zlata; Perkov, Sonja; Kardum Paro, Mirjana Mariana; Sikirica , Mirjana; Ožvald, Ivan; Šimonović, Barbara; Šurina, Branka
Applicability of the recommended reference intervals for serum creatinine concentrations // 18th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine, Innsbruck, Austria, June 7-11, 2009:W-A178. Clin Chem Lab Med 2009 ; 47, Special Suppl., S305.
Innsbruck: Walter de Gruyter, 2009. (poster, međunarodna recenzija, sažetak, stručni)
Flegar-Meštrić, Z., Perkov, S., Kardum Paro, M., Sikirica , M., Ožvald, I., Šimonović, B. & Šurina, B. (2009) Applicability of the recommended reference intervals for serum creatinine concentrations. U: 18th IFCC-EFCC European Congress of Clinical Chemistry and Laboratory Medicine, Innsbruck, Austria, June 7-11, 2009:W-A178. Clin Chem Lab Med 2009 ; 47, Special Suppl., S305..
@article{article, author = {Flegar-Me\v{s}tri\'{c}, Zlata and Perkov, Sonja and Kardum Paro, Mirjana Mariana and Sikirica, Mirjana and O\v{z}vald, Ivan and \v{S}imonovi\'{c}, Barbara and \v{S}urina, Branka}, year = {2009}, keywords = {calibration traceability, serum creatinie concentrations, enzymatic method}, title = {Applicability of the recommended reference intervals for serum creatinine concentrations}, keyword = {calibration traceability, serum creatinie concentrations, enzymatic method}, publisher = {Walter de Gruyter}, publisherplace = {Innsbruck, Austrija} }
@article{article, author = {Flegar-Me\v{s}tri\'{c}, Zlata and Perkov, Sonja and Kardum Paro, Mirjana Mariana and Sikirica, Mirjana and O\v{z}vald, Ivan and \v{S}imonovi\'{c}, Barbara and \v{S}urina, Branka}, year = {2009}, keywords = {calibration traceability, serum creatinie concentrations, enzymatic method}, title = {Applicability of the recommended reference intervals for serum creatinine concentrations}, keyword = {calibration traceability, serum creatinie concentrations, enzymatic method}, publisher = {Walter de Gruyter}, publisherplace = {Innsbruck, Austrija} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font