Performance characteristics and clinical usefulness of troponin I assays


Šimonović, Barbara; Ožvald, Ivan; Šurina, Branka; Šiftar, Zoran; Flegar-Meštrić, Zlata
Performance characteristics and clinical usefulness of troponin I assays // First European Joint Congress of EFCC and UEMS
Lisabon, 2010. (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 551349 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Performance characteristics and clinical usefulness of troponin I assays

Autori
Šimonović, Barbara ; Ožvald, Ivan ; Šurina, Branka ; Šiftar, Zoran ; Flegar-Meštrić, Zlata

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
First European Joint Congress of EFCC and UEMS / - Lisabon, 2010

Skup
First European Joint Congress of EFCC and UEMS

Mjesto i datum
Lisabon, Portugal, 13.10.2010. - 16.10.2010

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
myocardial cell damage; Troponin I assays; NCCLS Protocol EP5-A2; verification

Sažetak
Any condition resuting in myocardial cell damage can potentially increase cardiac troponin I levels. Therefor, low concentrations of troponin I have large clinical significance in diagnosis of pathological heart conditions. Materials and Methods A study was performed for the Axsym and Architect STAT Troponin I assays (Abbott Diagnostics). Axsym STAT Troponin I is a microparticle enzyme immunoassay (MEIA) ; Architect STAT Troponin I is a chemiluminiscent microparticle immunoassay (CMIA). Manufacturer's performance characteristics were verified according to NCCLS Protocol EP5-A2. A study was performed with STAT Troponin I Controls in two concentration levels ; n (Axsym)=20, n (Architect)=15 for each concentration level. According to do manufacturer's study, STAT Troponin I concentrations at 10 % CV were 0.16 µg/L for Axsym and 0.032 µg/L for Architect. Method comparison was performed on human serum (n=30) by linear regression analysis. Results Precision profile, including within-run precision CV%, for Axsym was 6.1 % (mean 0.28 µg/L) and 4.1 % (mean 1.14 µg/L), for Arcitect was 4.6 % (mean 0.14 µg/L) and 4.9 % (mean 0.56 µg/L) and within- laboratory precision for Axsym was 7.8 % and 5.3 %, for Architect was 5.6 % and 7.1 %. Comparison results all along measuring range (0.00-22.78 µg/L) showed r=0.92 (y=0.6138x+0.425). Conclusion STAT Troponin I CMIA has better analytical characteristics than MEIA. Methods are comparable because they are traceable to the same internal reference standard. As seen, analytical precision is not uniform among troponin I assays. The Commitee on Standardization of Markers of Cardiac Damage (C-SMCD) recommends a total precision CV% <10 at the myocardial infarction (MI) decision limit (0.028 µg/L). A failure to reach this goal could increase the risk of clinically misleading results. CMIA has advantage in clinical use because low concentrations of troponin I are significant in diagnosis of MI, angina, congestive heart failure, myocarditis.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinička bolnica "Merkur"


Citiraj ovu publikaciju:

Šimonović, Barbara; Ožvald, Ivan; Šurina, Branka; Šiftar, Zoran; Flegar-Meštrić, Zlata
Performance characteristics and clinical usefulness of troponin I assays // First European Joint Congress of EFCC and UEMS
Lisabon, 2010. (poster, međunarodna recenzija, sažetak, stručni)
Šimonović, B., Ožvald, I., Šurina, B., Šiftar, Z. & Flegar-Meštrić, Z. (2010) Performance characteristics and clinical usefulness of troponin I assays. U: First European Joint Congress of EFCC and UEMS.
@article{article, author = {\v{S}imonovi\'{c}, Barbara and O\v{z}vald, Ivan and \v{S}urina, Branka and \v{S}iftar, Zoran and Flegar-Me\v{s}tri\'{c}, Zlata}, year = {2010}, keywords = {myocardial cell damage, Troponin I assays, NCCLS Protocol EP5-A2, verification}, title = {Performance characteristics and clinical usefulness of troponin I assays}, keyword = {myocardial cell damage, Troponin I assays, NCCLS Protocol EP5-A2, verification}, publisherplace = {Lisabon, Portugal} }
@article{article, author = {\v{S}imonovi\'{c}, Barbara and O\v{z}vald, Ivan and \v{S}urina, Branka and \v{S}iftar, Zoran and Flegar-Me\v{s}tri\'{c}, Zlata}, year = {2010}, keywords = {myocardial cell damage, Troponin I assays, NCCLS Protocol EP5-A2, verification}, title = {Performance characteristics and clinical usefulness of troponin I assays}, keyword = {myocardial cell damage, Troponin I assays, NCCLS Protocol EP5-A2, verification}, publisherplace = {Lisabon, Portugal} }




Contrast
Increase Font
Decrease Font
Dyslexic Font