Pregled bibliografske jedinice broj: 549610
Cardiac Magnetic Resonance Imaging during Pulmonary Hyperinflation in Apnea Divers
Cardiac Magnetic Resonance Imaging during Pulmonary Hyperinflation in Apnea Divers // Medicine and science in sports and exercise, 43 (2011), 11; 2095-2101 doi:10.1249/MSS.0b013e31821ff294 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 549610 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Cardiac Magnetic Resonance Imaging during Pulmonary Hyperinflation in Apnea Divers
Autori
Batinić, Tonči ; Utz, W. ; Brešković, Toni ; Jordan, J. ; Schulz-Menger, J. ; Janković, Stipan ; Dujić, Željko ; Tank, J.
Izvornik
Medicine and science in sports and exercise (0195-9131) 43
(2011), 11;
2095-2101
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
diving physiology; glossopharyngeal insufflation; cardiac output; systolic function
Sažetak
Apnea divers hyperinflate the lung by taking a deep breath followed by glossopharyngeal insufflation. The maneuver can lead to symptomatic arterial hypotension. We tested the hypotheses that glossopharyngeal insufflation interferes with cardiac function further reducing cardiac output (CO) using cardiac magnetic resonance imaging (MRI) to fully sample both cardiac chambers. Eleven dive athletes (10 men, 1 woman ; age = 26 ± 5 yr, body mass index = 23.5 ± 1.7 kg·m) underwent cardiac MRI during breath holding at functional residual capacity (baseline), at total lung capacity (apnea), and with submaximal glossopharyngeal insufflation. Lung volumes were estimated from anatomic images. Short-axis cine MR images were acquired to study biventricular function. Dynamic changes were followed by long-axis cine MRI. Left and right ventricular end-diastolic volumes (LVEDV, RVEDV) decreased during apnea with and without glossopharyngeal insufflation (baseline: LVEDV = 198 ± 19 mL, RVEDV = 225 ± 30 mL ; apnea: LVEDV = 125 ± 38 mL, RVEDV = 148 ± 37 mL, P < 0.001 ; glossopharyngeal insufflation: LVEDV = 108 ± 26 mL, RVEDV = 136 ± 29 mL, P < 0.001 vs baseline). CO decreased during apnea (left = -29 ± 4 %, right = -29 ± 4 %) decreasing further with glossopharyngeal insufflation (left = -38% ± 4%, right = -39% ± 4%, P < 0.05). HR increased 16 ± 4 bpm with apnea and 17 ± 5 bpm with glossopharyngeal insufflation (P < 0.01). Ejection fraction moderately decreased (apnea: left = -5% ± 2%, right = -7% ± 2%, glossopharyngeal insufflation: left = -6% ± 2%, right = -10% ± 2%, P < 0.01). With continued apnea with and without glossopharyngeal insufflation, LVEDV and CO increased over time by a similar but small amount (P < 0.01). The major finding of our study was that submaximal glossopharyngeal insufflation decreased CO further albeit by a small amount compared to maximal inspiratory apnea. The response was not associated with severe biventricular dysfunction.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti
POVEZANOST RADA
Projekti:
216-2160133-0130 - Ronjenje s komprimiranim zrakom i kardiovaskularni sustav (Dujić, Željko, MZOS ) ( CroRIS)
Ustanove:
Medicinski fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE