Pregled bibliografske jedinice broj: 531328
Experimental Testing of the Sports Hall Roof Structure "Arena Zagreb"
Experimental Testing of the Sports Hall Roof Structure "Arena Zagreb" // Proceedings of the 5th International Conference on Engineering Surveying / Kopáčik, Alojz ; Kyrinovič, Peter ; Roić, Miodrag (ur.).
Zagreb: Geodetski fakultet Sveučilišta u Zagrebu, 2011. str. 237-244 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 531328 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Experimental Testing of the Sports Hall Roof Structure "Arena Zagreb"
Autori
Marendić, Ante ; Paar, Rinaldo ; Kapović, Zdravko ; Novaković, Gorana ; Babić, Krešimir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 5th International Conference on Engineering Surveying
/ Kopáčik, Alojz ; Kyrinovič, Peter ; Roić, Miodrag - Zagreb : Geodetski fakultet Sveučilišta u Zagrebu, 2011, 237-244
ISBN
978-953-6082-15-5
Skup
5th International Conference on Engineering Surveying - INGEO 2011
Mjesto i datum
Brijuni, Hrvatska, 22.09.2011. - 24.09.2011
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
roof structure; experimental testing; deformation; robotic total station
Sažetak
"Arena Zagreb" sports hall which was built for the maintenance of 21st Handball World Championships held in Zagreb in 2009 is the object of special importance. The roof structure of the hall is nearly rectangular shaped ground plan dimensions of 143.0 x 103.6 m. It consists of curved main steel girders suspended steel tie rods to the tops of the facade of concrete beams in the east-west direction and secondary steel beams in a north-south direction. Since this is a sports hall, where during sports events there is a large number of people and considering it's particularly complex shape and design construction, the applicable Croatian legislation for steel structures (HRN U. M1. 047 – OG 139/09) require an experimental testing. With this testing, before obtaining a use permit, it is checked whether the construction is technically correct and suitable to take the project anticipated loads. In this paper a static load test of the roof main beams of "Arena Zagreb" with the application of geodetic surveying methods will be presented. The most interesting test results obtained by classical geodetic surveying methods, using modern robotic total stations, will be presented.
Izvorni jezik
Engleski
Znanstvena područja
Geodezija
POVEZANOST RADA
Ustanove:
Geodetski fakultet, Zagreb
Profili:
Rinaldo Paar
(autor)
Zdravko Kapović
(autor)
Gorana Novaković
(autor)
Krešimir Babić
(autor)
Ante Marendić
(autor)