Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in Co- 60 beams
Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in Co- 60 beams // Physics in medicine and biology, 56 (2011), 18; 6065-6082 doi:10.1088/0031-9155/56/18/018 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 527236 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Optically stimulated luminescence in vivo
dosimetry for radiotherapy: physical
characterization and clinical measurements in Co-
60 beams
Autori
Mrčela, Iva ; Bokulić, Tomislav ; Izewska, Joanna ; Budanec, Mirjana ; Frobe, Ana ; Kusić, Zvonko
Izvornik
Physics in medicine and biology (0031-9155) 56
(2011), 18;
6065-6082
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
In vivo dosimetry ; OSL ; radiotherapy
Sažetak
A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in 60Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in repeated irradiations of the same dosimeters it was found to be 3.5%. When OSL dosimeters were optically bleached between exposures, the reproducibility of repeated measurements improved to 1.0%. Dosimeters were calibrated for the entrance dose measurements and a full set of correction factors was determined. A pilot patient study that followed phantom validation testing included more than 100 measured fields with a mean relative difference of the measured entrance dose from the expected dose of 0.8% and the standard deviation of 2.5%. In conclusion, these results demonstrate that OSL dot dosimeters represent a valid alternative to already established in vivo dosimetry systems.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
KBC "Sestre Milosrdnice"
Profili:
Iva Mrčela
(autor)
Ana Fröbe
(autor)
Zvonko Kusić
(autor)
Mirjana Budanec
(autor)
Tomislav Bokulić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE