Pregled bibliografske jedinice broj: 52564
"CAMUS 3" International Benchmark : After test comparison of numerical and experimental results
"CAMUS 3" International Benchmark : After test comparison of numerical and experimental results // ICONS - European program seismic tests on r/c bearing walls-Camus III specimen / Combesure, D. ; Chaudat, Th. (ur.).
Saclay : Pariz: Commissariat a L'Energie Atomique, 2001. str. 215-230
CROSBI ID: 52564 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
"CAMUS 3" International Benchmark : After test comparison of numerical and experimental results
Autori
Sigmund, Vladimir ; Guljaš, Ivica ; Matošević, Đurđica
Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, znanstveni
Knjiga
ICONS - European program seismic tests on r/c bearing walls-Camus III specimen
Urednik/ci
Combesure, D. ; Chaudat, Th.
Izdavač
Commissariat a L'Energie Atomique
Grad
Saclay : Pariz
Godina
2001
Raspon stranica
215-230
Ključne riječi
r/c wall, seismic test, numerical modelling, comparisson
Sažetak
A part of the TMR (Training and Mobility of Researchers) of the 5th Topic � Shear Wall Structures� of the European Program ICONS (� Innovative Seismic Design Concepts for New and Existing Structures� ) was to perform a series of seismic tests on a 5-story structure. The set up was the same as for the previous French CAMUS experiment, but the new structure followed the EC8 provisions with the behavior reduction coefficient q=3.5. The 1/3rd scaled model of the walls, "Camus 3", consisted of two parallel 5-floor r/c walls without openings connected by 6 square floors. A heavily reinforced concrete footing allowed the anchorage to the shaking table. The tests were performed on the Azalee shaking table of the EMSI Laboratory in Sacley, France. [1], [2]. A series of seismic tests were realized with 2 types of seismic records. An artificial signal NICE was used for the low-level initial and high-level ultimate tests. The natural signal MELENDY RANCH represented a near-field high-magnitude seismic record and was used for the intermediate tests. The tests were performed until the model structure collapsed. The Faculty of Civil Engineering in Osijek participated in the project by making a blind prediction of the "CAMUS 3" model seismic response to a given set of earthquakes [3]. The main objective of that first phase was to check the ability of macro elements and a standard computer code to predict global and local wall response parameters. The platform for the nonlinear analysis of the structural systems was the program LARZ [6] that had been developed through calibration using results from dynamic tests of reinforced concrete structural systems incorporating frames and walls. After finishing the first phase study and collecting the predicted response from cca. 10 institutions the complete test results were publicized [2]. In this report a final comparison between the calculated (with slight model improvements) and the measured results is presented.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo
Napomena
The CAMUS III experiment is part of the 5th Topic "Shear Wall Structures" of the European program ICONS-TMR ("Innovative Seismic Design Concepts for New and Existing Structures– Training and Mobility of Researchers") and of ECOEST2 ("European Consortium of Earthquake Shaking Tables") ; CAFEEL-ECOEST/ICONS Thematic report N.5. Shear walls structures. Reynouard, J.M. ; Fardis, M.N. (Eds.) ; Severn, R.T. ; Bairrã o, R. (Gen. Eds.) ; LNEC, September, 2001. for the final report.