Pregled bibliografske jedinice broj: 504572
Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor
Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor // Second Regional Symposium on Electrochemistry South-East Europe, Program & Book of Abstracts / Nikolić, Branislav ; Mišković-Stanković, Vesna ; Dekanski, Aleksandar (ur.).
Beograd: Serbian Chemical Society, 2010. str. 74-74 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 504572 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Simultaneous potentiometric determination of cationic and ethoxylated nonionic surfactants by use of a surfactant sensor
Autori
Samardžić, Mirela ; Sak-Bosnar, Milan ; Madunić-Čačić, Dubravka
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Second Regional Symposium on Electrochemistry South-East Europe, Program & Book of Abstracts
/ Nikolić, Branislav ; Mišković-Stanković, Vesna ; Dekanski, Aleksandar - Beograd : Serbian Chemical Society, 2010, 74-74
ISBN
978-86-7132-043-6
Skup
Second Regional Symposium on Electrochemistry South-East Europe
Mjesto i datum
Beograd, Srbija, 06.06.2010. - 10.06.2010
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
surfactant sensor; cationic surfactant; ethoxylated nonionic surfactant; potentiometric titration
Sažetak
A sensitive potentiometric surfactant sensor based on 1, 3-didecyl-2-methylimidazolium-tetraphenylborate as a sensing ion-pair element served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. A few mixtures containing a cationic and ethoxylated nonionic surfactant were titrated potentiometrically. Barium ions forms pseudocationic complex with ethoxylated nonionic surfactant that can be titrated simultaneously with cationic surfactant using the same anionic titrant. Due to differences in hydrophobicity of both, nonionic and cationic surfactant investigated, ion associates formed during the titration revealed different stability constants resulting in two, more or less pronounced, analytically usable inflexions in the titration curve. The sensor showed satisfactory analytical performances within a pH range of two through eleven and was tested on several formulated powdered and liquid detergent products of various composition complexity too.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)
Ustanove:
Sveučilište u Osijeku - Odjel za kemiju