Pregled bibliografske jedinice broj: 504556
The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants
The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants // International Journal of Electrochemical Science, 6 (2011), 3; 561-572 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 504556 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The influence of ethoxylated nonionic surfactants on the potentiometric determination of anionic surfactants
Autori
Sak-Bosnar, Milan ; Samardžić, Mirela ; Galović, Olivera
Izvornik
International Journal of Electrochemical Science (1452-3981) 6
(2011), 3;
561-572
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
ion sensitive sensor; anionic surfactant; ethoxylated nonionic surfactant; potentiometric titration
Sažetak
A PVC-plasticized liquid-type anionic surfactant (AS)-responsive sensor, using 1, 3-didecyl-2- methylimidazolium-tetraphenylborate (DMI-TPB) as the sensing element, has been utilized for the investigation of the influence of three ethoxylated nonionic surfactants (EONS), containing 8, 11 and 15 ethoxy (EO) groups, on the potentiometric determination of dodecyl sulfate (DS). The results demonstrate that the sensor slope (S) slowly decreased with increasing concentrations of EONS. The changes in the slope for the corresponding concentration change (DS:EONS ratios varied from 1:1 to 1:4) were 1.62, 5.11 and 6.28 mV for EONS containing 8, 11 and 15 EO groups, respectively. The constant potential term changes for the same EONS concentration change were 18.8, 22.3 and 39.5 mV, respectively. The linear response range became more narrow as the concentration of EONS increased, and increasing numbers of EO groups were found within the EONS molecule. There was a strong correlation between E and log DS a for all of the DS:EONS ratios in the linear region of the sensor response. The EONS molecules significantly influenced the potentiometric titration of DS. The titration curves were seriously disturbed for EONS:DS molar ratios greater than 5 for EONS containing 8 EO groups, for ratios greater than 3 for EONS containing 11 EO groups and for ratios greater than 2 for EONS containing 15 EO groups.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)
Ustanove:
Sveučilište u Osijeku - Odjel za kemiju
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus