Pregled bibliografske jedinice broj: 501212

Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation


Grgić, Davor; Benčik, Vesna; Šadek, Siniša
Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation // Proceedings of the International Conference Nuclear Energy for New Europe 2010 / Trkov, Andrej ; Lengar, Igor (ur.).
Ljubljana: Nuclear Society of Slovenia, 2010. str. 415.1-415.11 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 501212 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation

Autori
Grgić, Davor ; Benčik, Vesna ; Šadek, Siniša

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the International Conference Nuclear Energy for New Europe 2010 / Trkov, Andrej ; Lengar, Igor - Ljubljana : Nuclear Society of Slovenia, 2010, 415.1-415.11

ISBN
978-961-6207-31-7

Skup
International Conference Nuclear Energy for New Europe 2010

Mjesto i datum
Portorož, Slovenija, 06.09.2010. - 09.09.2010

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
RELAP; GOTHIC; coupled code; containment

Sažetak
Using one Steam Line Break scenario and one Stuck Open PORV scenario, originally developed for Krsko Full Scope Simulator, the benefits of coupled system-containment code usage over classical two-steps calculation procedure were demonstrated. RELAP5 mod3.3, GOTHIC and coupled RELAP5-GOTHIC code R5G were used to perform classical mass and energy and then containment calculation and coupled code calculation. For most of the design bases accidents and transients in current Light Water Reactors level of interaction between system and containment is low and decoupled system and containment runs can be performed. It is demonstrated that coupled code, once when it is available, can be easier to use, can give better prediction, and can reduce possibility of error during manipulation with mass and energy release data. Additional benefits are available when coupled code can share trips generated in system and containment part of the code.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0361590-1589 - Nuklearne elektrane za održivu proizvodnju električne energije (Feretić, Danilo, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Siniša Šadek (autor)

Avatar Url Davor Grgić (autor)

Avatar Url Vesna Benčik (autor)


Citiraj ovu publikaciju:

Grgić, Davor; Benčik, Vesna; Šadek, Siniša
Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation // Proceedings of the International Conference Nuclear Energy for New Europe 2010 / Trkov, Andrej ; Lengar, Igor (ur.).
Ljubljana: Nuclear Society of Slovenia, 2010. str. 415.1-415.11 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Grgić, D., Benčik, V. & Šadek, S. (2010) Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation. U: Trkov, A. & Lengar, I. (ur.)Proceedings of the International Conference Nuclear Energy for New Europe 2010.
@article{article, author = {Grgi\'{c}, Davor and Ben\v{c}ik, Vesna and \v{S}adek, Sini\v{s}a}, year = {2010}, pages = {415.1-415.11}, keywords = {RELAP, GOTHIC, coupled code, containment}, isbn = {978-961-6207-31-7}, title = {Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation}, keyword = {RELAP, GOTHIC, coupled code, containment}, publisher = {Nuclear Society of Slovenia}, publisherplace = {Portoro\v{z}, Slovenija} }
@article{article, author = {Grgi\'{c}, Davor and Ben\v{c}ik, Vesna and \v{S}adek, Sini\v{s}a}, year = {2010}, pages = {415.1-415.11}, keywords = {RELAP, GOTHIC, coupled code, containment}, isbn = {978-961-6207-31-7}, title = {Comparison of R5G Coupled Code and Classical “Two-steps” Containment Calculation}, keyword = {RELAP, GOTHIC, coupled code, containment}, publisher = {Nuclear Society of Slovenia}, publisherplace = {Portoro\v{z}, Slovenija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font