Pregled bibliografske jedinice broj: 497456
Assessment of the backflashover occurrence rate on HV transmission line towers
Assessment of the backflashover occurrence rate on HV transmission line towers // European transactions on electrical power, 22 (2012), 2; 152-169 doi:10.1002/etep.552 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 497456 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Assessment of the backflashover occurrence rate on HV transmission line towers
Autori
Sarajčev, Petar ; Goić, Ranko
Izvornik
European transactions on electrical power (1430-144X) 22
(2012), 2;
152-169
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
lightning; transmission line; tower; backflashover; statistical distribution; correlation coefficient
Sažetak
An assessment of the backflashover occurrence rate on the high voltage (HV) transmission line towers is presented in this paper. It is based on a mathematical model that accounts for the transmission line geometry, keraunic level, statistical distribution of lightning current parameters, and correlation between statistical variables defining the lightning current waveshape. Furthermore, assessment of the backflashover occurrence rate on these towers accounts for the tower footing impulse resistance, lightning impulse insulation strength of the insulator strings and surge impedance of the tower itself. Proposed theoretical analysis is backed by the most recent propositions of parameters that define statistical distributions of lightning current parameters and then applied to the typical HV transmission line example. This analysismight be useful when scrutinizing the several first transmission line towers incoming to the HV substations. Hence, here presented analysis could be subsequently applied for the design of the HV substation overvoltage protection. Finally, a sensitivity analysis is provided, in regards to the parameters of the log-normal distributions defining lightning current amplitude and steepness, as well as in regards to the tower footing impulse resistance.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
023-0000000-3271 - Razvoj naprednih algoritama za modeliranje elektromagnetskih pojava (Vujević, Slavko, MZOS ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus