Pregled bibliografske jedinice broj: 490817
Copper(II) ion selective electrode based on 1, 2- di-(o-salicylaldiminophenylthio)ethane
Copper(II) ion selective electrode based on 1, 2- di-(o-salicylaldiminophenylthio)ethane // XXI Skup kemičara i kemijskih inženjera
Trogir, Hrvatska, 2009. (poster, nije recenziran, sažetak, znanstveni)
CROSBI ID: 490817 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Copper(II) ion selective electrode based on 1, 2- di-(o-salicylaldiminophenylthio)ethane
Autori
Buzuk, Marijo ; Brinić Slobodan ; Generalić, Eni ; Caktaš, Filipa ; Bralić Marija
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
XXI Skup kemičara i kemijskih inženjera
/ - , 2009
Skup
XXI. Skup kemičara i kemijskih inženjera
Mjesto i datum
Trogir, Hrvatska, 19.04.2009. - 22.04.2009
Vrsta sudjelovanja
Poster
Vrsta recenzije
Nije recenziran
Ključne riječi
ionophore; copper(II); ion selective; potentiometry
Sažetak
1, 2-di-(o-salicylaldiminophenylthio)ethane was synthesized and used as ion carrier in the fabrication of copper(II) ion selective PVC membrane electrodes. Influence of different component ratio, and different plasticizer were study for obtaining a sensor with optimal response characteristic for determination of copper(II) in water sample in wide pH range. The best performances are obtained by a membrane electrode having o-NPOE as plasticizer and and NaTBP as anionic additive (1/2 mole ratio in respect to ion carrier). This electrode shows a linear potential response to copper(II) in concentration range 9×10-7 - 1×10-2 moldm-3, with Nernstian slope of 29.5 mV/decade and detection limit down to 5×10-7 moldm-3. It is suitable for copper(II) determinations within pH between 3.5 and 7.3, and work well over a period of 2 months. The potentiometric selectivity coefficient value ( ) as determinated by fixed interference method indicate excellent selectivity for Cu2+ ions over interfering cations. There were no noticed any interference by chlorides and other examined anions. Described membrane electrode can be used in analytical measurements by direct potentiometry as well in potentiometric titration.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
011-1252970-2254 - Cementni kompoziti i stabilizacija štetnih otpada (NOMACIS) (Krolo, Petar, MZOS ) ( CroRIS)
Ustanove:
Kemijsko-tehnološki fakultet, Split
Profili:
Eni Generalić
(autor)
Marijo Buzuk
(autor)
Slobodan Brinić
(autor)
Filipa Caktaš Šagi
(autor)