Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 489667

Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer


Joulaeizadeh, L.; Gašparić, Igor; Bacelar, J.; Čaplar, Roman; Lohner, H.
Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 622 (2010), 1; 176-181 doi:10.1016/j.nima.2010.06.204 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 489667 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer

Autori
Joulaeizadeh, L. ; Gašparić, Igor ; Bacelar, J. ; Čaplar, Roman ; Lohner, H.

Izvornik
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (0168-9002) 622 (2010), 1; 176-181

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
CsI(Tl) scintillator ; Light output ; Energy calibration ; Cosmic muons

Sažetak
A 2 pi hemispherical detector consisting of 64 CsI(Tl) scintillator modules covering the angular range of 80 degrees -160 degrees has been constructed. This detector is employed as the Inner Shell of the Plastic Ball detector and was used in two experimental programs concerning the study of pionic fusion in light-ion systems. The geometry and construction are presented. The improved response of the combined detectors for photons are discussed. An energy calibration method using high energy cosmic muons for the Inner Shell and the Plastic Ball has been developed and the calibration results are compared to the results of the same method in the Monte-Carlo simulation. The improved acceptance of the combined detectors for the pi(0) detection in the Li-6(He-4, pi(0))B-10* experiment are presented and discussed.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
098-1191005-2879 - Fizika teških iona (Basrak, Zoran, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Igor Gašparić (autor)

Avatar Url Roman Čaplar (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Joulaeizadeh, L.; Gašparić, Igor; Bacelar, J.; Čaplar, Roman; Lohner, H.
Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 622 (2010), 1; 176-181 doi:10.1016/j.nima.2010.06.204 (međunarodna recenzija, članak, znanstveni)
Joulaeizadeh, L., Gašparić, I., Bacelar, J., Čaplar, R. & Lohner, H. (2010) Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer. Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 622 (1), 176-181 doi:10.1016/j.nima.2010.06.204.
@article{article, author = {Joulaeizadeh, L. and Ga\v{s}pari\'{c}, Igor and Bacelar, J. and \v{C}aplar, Roman and Lohner, H.}, year = {2010}, pages = {176-181}, DOI = {10.1016/j.nima.2010.06.204}, keywords = {CsI(Tl) scintillator, Light output, Energy calibration, Cosmic muons}, journal = {Nuclear instruments and methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment}, doi = {10.1016/j.nima.2010.06.204}, volume = {622}, number = {1}, issn = {0168-9002}, title = {Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer}, keyword = {CsI(Tl) scintillator, Light output, Energy calibration, Cosmic muons} }
@article{article, author = {Joulaeizadeh, L. and Ga\v{s}pari\'{c}, Igor and Bacelar, J. and \v{C}aplar, Roman and Lohner, H.}, year = {2010}, pages = {176-181}, DOI = {10.1016/j.nima.2010.06.204}, keywords = {CsI(Tl) scintillator, Light output, Energy calibration, Cosmic muons}, journal = {Nuclear instruments and methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment}, doi = {10.1016/j.nima.2010.06.204}, volume = {622}, number = {1}, issn = {0168-9002}, title = {Design, instrumentation and response characteristics of a 2 pi multi-detector of CsI(Tl) scintillators mounted inside the Plastic Ball spectrometer}, keyword = {CsI(Tl) scintillator, Light output, Energy calibration, Cosmic muons} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font