Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis


Bralić, Marija; Generalić, Eni; Krka, Silvestar
Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis // Analytical Letters, 33 (2000), 9; 1811-1825 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 48489 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis

Autori
Bralić, Marija ; Generalić, Eni ; Krka, Silvestar

Izvornik
Analytical Letters (0003-2719) 33 (2000), 9; 1811-1825

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
fluoride ion-selective electrode; FISE; flow injection analysis; FIA; tubular detector; potentiometry

Sažetak
Design of the fluoride ion-selective electrode (FISE) as the tubular detector used in the flow injection analysis (FIA) has been described. Among other things, this design makes it possible to use various internal contacts. The effect of pH on peak height and detection limit in the pH range from 2.8 to 8.0 has been examined. The effect of flow rate and sample injection volume on peak height and range of linear response has also been examined. The flow rates rang from 0.56 mL/min to 4.05 mL/min, while the injection volumes are 100 and 200 mL. The optimum conditions are carrier solution (0.1 M KNO3, buffer pH 4 and 10-6 M NaF), flow rate 1.54 mL/min and sample injection volume 100 mL. Applicability of FISE as the tubular detector in determination of Fe(III)-ions and Al(III)-ions by flow injection analysis has been examined at pH values of 2.8; and 3.4.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
011005

Ustanove:
Kemijsko-tehnološki fakultet, Split

Profili:

Avatar Url Silvestar Krka (autor)

Avatar Url Marija Bralić (autor)

Avatar Url Eni Generalić (autor)


Citiraj ovu publikaciju:

Bralić, Marija; Generalić, Eni; Krka, Silvestar
Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis // Analytical Letters, 33 (2000), 9; 1811-1825 (međunarodna recenzija, članak, znanstveni)
Bralić, M., Generalić, E. & Krka, S. (2000) Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis. Analytical Letters, 33 (9), 1811-1825.
@article{article, author = {Brali\'{c}, Marija and Generali\'{c}, Eni and Krka, Silvestar}, year = {2000}, pages = {1811-1825}, keywords = {fluoride ion-selective electrode, FISE, flow injection analysis, FIA, tubular detector, potentiometry}, journal = {Analytical Letters}, volume = {33}, number = {9}, issn = {0003-2719}, title = {Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis}, keyword = {fluoride ion-selective electrode, FISE, flow injection analysis, FIA, tubular detector, potentiometry} }
@article{article, author = {Brali\'{c}, Marija and Generali\'{c}, Eni and Krka, Silvestar}, year = {2000}, pages = {1811-1825}, keywords = {fluoride ion-selective electrode, FISE, flow injection analysis, FIA, tubular detector, potentiometry}, journal = {Analytical Letters}, volume = {33}, number = {9}, issn = {0003-2719}, title = {Design of the Fluoride Ion-Selective Electrode as Tubular Detector for Flow Injection Analysis}, keyword = {fluoride ion-selective electrode, FISE, flow injection analysis, FIA, tubular detector, potentiometry} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus





Contrast
Increase Font
Decrease Font
Dyslexic Font