Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers


Miloš, Marija; Coen Herak, desiree; Zadro, Renata
Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers // International journal of laboratory hematology, 32 (2010), 1 Part 2; 33-39 doi:10.1111/j.1751-553X.2008.01111.x (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 478845 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers

Autori
Miloš, Marija ; Coen Herak, desiree ; Zadro, Renata

Izvornik
International journal of laboratory hematology (1751-5521) 32 (2010), 1 Part 2; 33-39

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
activated partial thromboplastin time; evaluation mode; reaction curve; visual analysis; coagulation analyzers

Sažetak
Modern photo-optical coagulometers collect optical data in the form of reaction curves and offer a possibility to determine clotting times at different points of clot formation by using different evaluation modes. The objectives of this study were to determine the possible impact of an evaluation mode on activated partial thromboplastin time (APTT) results and to investigate potential benefits from visual inspection of obtained reaction curves. APTT was determined by using actin FS as reagent on two coagulometers (Siemens Medical Solutions) in 174 plasma samples with three different evaluation modes: fixed absorbance(FA), drifting baseline (DB), and point of inflexion (POI) on Behring coagulation timer (BCT), and with DB mode on Behring coagulation system (BCS). Statistically significant difference of APTT results applying the Friedman’s test (P < 0.0001) followed by Dunn’s multiple comparison test (P < 0.05) was obtained in all tested samples between POI mode and all other evaluation modes, independently of analyzer used. The differences obtained indicated that laboratory professionals must be aware of possible different evaluation modes on different analyzers, and establish evaluation mode-specific reference intervals. Moreover, correctness of a reported result could be confirmed only by visual analysis of the reaction curve.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Farmacija



POVEZANOST RADA


Projekti:
0214212

Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Renata Zadro (autor)

Avatar Url Marija Miloš (autor)

Poveznice na cjeloviti tekst rada:

doi onlinelibrary.wiley.com

Citiraj ovu publikaciju:

Miloš, Marija; Coen Herak, desiree; Zadro, Renata
Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers // International journal of laboratory hematology, 32 (2010), 1 Part 2; 33-39 doi:10.1111/j.1751-553X.2008.01111.x (međunarodna recenzija, članak, znanstveni)
Miloš, M., Coen Herak, d. & Zadro, R. (2010) Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers. International journal of laboratory hematology, 32 (1 Part 2), 33-39 doi:10.1111/j.1751-553X.2008.01111.x.
@article{article, author = {Milo\v{s}, Marija and Coen Herak, desiree and Zadro, Renata}, year = {2010}, pages = {33-39}, DOI = {10.1111/j.1751-553X.2008.01111.x}, keywords = {activated partial thromboplastin time, evaluation mode, reaction curve, visual analysis, coagulation analyzers}, journal = {International journal of laboratory hematology}, doi = {10.1111/j.1751-553X.2008.01111.x}, volume = {32}, number = {1 Part 2}, issn = {1751-5521}, title = {Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers}, keyword = {activated partial thromboplastin time, evaluation mode, reaction curve, visual analysis, coagulation analyzers} }
@article{article, author = {Milo\v{s}, Marija and Coen Herak, desiree and Zadro, Renata}, year = {2010}, pages = {33-39}, DOI = {10.1111/j.1751-553X.2008.01111.x}, keywords = {activated partial thromboplastin time, evaluation mode, reaction curve, visual analysis, coagulation analyzers}, journal = {International journal of laboratory hematology}, doi = {10.1111/j.1751-553X.2008.01111.x}, volume = {32}, number = {1 Part 2}, issn = {1751-5521}, title = {Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers}, keyword = {activated partial thromboplastin time, evaluation mode, reaction curve, visual analysis, coagulation analyzers} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font