Pregled bibliografske jedinice broj: 477865
The addition of a brief ultrasound examination to clinical assessment increases the ability to confirm placement of double-lumen endotracheal tubes
The addition of a brief ultrasound examination to clinical assessment increases the ability to confirm placement of double-lumen endotracheal tubes // Journal of clinical anesthesia, 22 (2010), 4; 246-249 doi:10.1016/j.jclinane.2009.07.010 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 477865 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The addition of a brief ultrasound examination to clinical assessment increases the ability to confirm placement of double-lumen endotracheal tubes
Autori
Šustić, Alan ; Protić, Alen ; Cicvarić, Tedi ; Župan, Željko
Izvornik
Journal of clinical anesthesia (0952-8180) 22
(2010), 4;
246-249
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
ultrasound; double-lumen endotracheal tube
Sažetak
Study objhective was to evaluate the role of a brief ultrasound examination (US) in detecting the correct position of the left double-lumen endotracheal tube (LDLT). Design was prospective, randomized clinical study. Setting was operating room of a university hospital. 50 elective adult thoracic surgery patients who required a LDLT during anesthesia. Patients were randomized to two groups: Group A, who underwent clinical assessment of the LDLT position, and Group B, who were examined clinically and by ultrasound. All 50 patients underwent the same conventional procedure of LDLT placement. In all patients, clinical assessment of LDLT positioning was made by observing chest wall expansion and checking lung compliance by manual ventilation and by auscultation of both lungs. In Group B, a very brief ultrasound (15-30 sec) examination was added. Ultrasound examination included visualization of the pleural movements ("lung sliding") and motion of the diaphragm from both sides before and after selective clamping of the bronchial and tracheal limbs. In both groups, a second anesthesiologist performed bronchoscopy to estimate actual LDLT position. Sensitivity and negative predictive values in detecting proper LDLT positioning for both methods were 100%. For the clinical assessment alone (Group A), specificity was 22%, accuracy was 72%, and positive predictive value, 70% ; for the clinical and ultrasound assessment (Group B), specificity was 50%, accuracy was 88%, and positive predictive value, 86%. A brief ultrasound examination added to clinical assessment ensured more precise placement of LDLT than did clinical assessment alone.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
062-0000000-0220 - Perkutana traheostomija u prevenciji pneumonije u strojno ventiliranih bolesnika (Šustić, Alan, MZOS ) ( CroRIS)
Ustanove:
Medicinski fakultet, Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE