Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 464753

Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing


Marjanović, Damir; Kovačević, Lejla; Durmić, Adaleta; Avdić, Jasna; Hindija, Jasmina; Škaro, Vedrana; Projić, Petar; Primorac, Dragan
Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing // 19th International Symposium in Human Identification, Hollywood, SAD, Abstract book
Hollywood (FL), Sjedinjene Američke Države, 2008. str. 26-26 (poster, nije recenziran, sažetak, ostalo)


CROSBI ID: 464753 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing

Autori
Marjanović, Damir ; Kovačević, Lejla ; Durmić, Adaleta ; Avdić, Jasna ; Hindija, Jasmina ; Škaro, Vedrana ; Projić, Petar ; Primorac, Dragan

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, ostalo

Izvornik
19th International Symposium in Human Identification, Hollywood, SAD, Abstract book / - , 2008, 26-26

Skup
19th International Symposium in Human Identification,

Mjesto i datum
Hollywood (FL), Sjedinjene Američke Države, 2008

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
PowerPlex S5 Mini-STR System; LCN DNA Testing

Sažetak
INTRODUCTION: The primary value of DNA typing has been significantly increased in last fifteen years due to introduction of short tandem repeat (STR) loci in routine paternity testing, as well as in forensic cases and mass disaster human identification. Nevertheless, ability to obtain DNA profiles from very small amounts of sample still presents certain type of challenge in forensic casework. As it is already known, low-copy number (LCN) DNA testing typically refers to examination of less than 100 pg of input DNA. In this analysis the number of PCR cycles is often increased to improve the amplification yield. Nevertheless, application of LCN results should be approached with caution due to the possibilities of allele dropout, allele drop-in, and increased risks of collection-based and laboratory based contamination. Therefore, sometimes, additional DNA analysis of these samples is required to be performed with an available miniSTR system. CASE DESCRIPTION: Two single hairs, which were provided to our laboratory, were microscopically observed. Hair root, with extremely poor presence of epithelial cells, was detected on both of them. In addition, both samples were briefly washed in absolute ethanol and extracted by usage of the Qiagen DnaeasyTM Tissue Kit. DNA concentration was determined using Quantifiler Human DNA Quantification Kit as described previously. The reaction was carried out in AB 7300 Real-Time PCR System according to the manufacturer’s recommendations. Mesured mean quantity was 1.40 × 10−2 ng/μL for the first and 3.20 × 10−2 ng/μL for the second sample. Initially, the PowerPlex16 kit has been used to amplify 15 STR loci. The total volume of each reaction was 10μL. The PCR amplification was carried out in PE Gene Amp PCR System Thermal Cycler. The number of cycles was increased to 32 and elongation time extended to 90 seconds. The very same protocol we are already successfully using in analysis of degraded bone samples from WWII. But this time, we have obtained partial DNA profiles with few possible allele dropouts, allele drop-in situation. Therefore, amplification step using PowerPlex S5system was additionally performed. The total volume of each reaction was 10μL. As the result of that, full and clean profiles (over all 5 loci) were obtained for both samples. That helped us in final distinction of real alleles on the one, and stochastic fluctuation on the other side over the analyzed loci.

Izvorni jezik
Engleski

Znanstvena područja
Biologija, Etnologija i antropologija



POVEZANOST RADA


Projekti:
309-1300855-2738 - Razvoj sustava za DNA analizu arheoloških koštanih uzoraka

Ustanove:
GENOS d.o.o.

Profili:

Avatar Url Petar Projić (autor)

Avatar Url Dragan Primorac (autor)

Avatar Url Damir Marjanović (autor)

Avatar Url Vedrana Škaro (autor)


Citiraj ovu publikaciju:

Marjanović, Damir; Kovačević, Lejla; Durmić, Adaleta; Avdić, Jasna; Hindija, Jasmina; Škaro, Vedrana; Projić, Petar; Primorac, Dragan
Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing // 19th International Symposium in Human Identification, Hollywood, SAD, Abstract book
Hollywood (FL), Sjedinjene Američke Države, 2008. str. 26-26 (poster, nije recenziran, sažetak, ostalo)
Marjanović, D., Kovačević, L., Durmić, A., Avdić, J., Hindija, J., Škaro, V., Projić, P. & Primorac, D. (2008) Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing. U: 19th International Symposium in Human Identification, Hollywood, SAD, Abstract book.
@article{article, author = {Marjanovi\'{c}, Damir and Kova\v{c}evi\'{c}, Lejla and Durmi\'{c}, Adaleta and Avdi\'{c}, Jasna and Hindija, Jasmina and \v{S}karo, Vedrana and Proji\'{c}, Petar and Primorac, Dragan}, year = {2008}, pages = {26-26}, keywords = {PowerPlex S5 Mini-STR System, LCN DNA Testing}, title = {Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing}, keyword = {PowerPlex S5 Mini-STR System, LCN DNA Testing}, publisherplace = {Hollywood (FL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Marjanovi\'{c}, Damir and Kova\v{c}evi\'{c}, Lejla and Durmi\'{c}, Adaleta and Avdi\'{c}, Jasna and Hindija, Jasmina and \v{S}karo, Vedrana and Proji\'{c}, Petar and Primorac, Dragan}, year = {2008}, pages = {26-26}, keywords = {PowerPlex S5 Mini-STR System, LCN DNA Testing}, title = {Usage of the PowerPlex® S5 Mini-STR System in LCN DNA Testing}, keyword = {PowerPlex S5 Mini-STR System, LCN DNA Testing}, publisherplace = {Hollywood (FL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font