Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 464157

Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS)


Babić, Sandra; Mutavdžić Pavlović, Dragana; Ašperger, Danijela; Periša, Martina; Zrnčić, Mirta; Horvat, Alka J.M.; Kaštelan-Macan, Marija
Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS) // Analytical & bioanalytical chemistry, 398 (2010), 3; 1185-1194 doi:10.1007/s00216-010-4004-1 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 464157 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS)

Autori
Babić, Sandra ; Mutavdžić Pavlović, Dragana ; Ašperger, Danijela ; Periša, Martina ; Zrnčić, Mirta ; Horvat, Alka J.M. ; Kaštelan-Macan, Marija

Izvornik
Analytical & bioanalytical chemistry (1618-2642) 398 (2010), 3; 1185-1194

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
pharmaceuticals ; wastewater ; liquid chromatography-tandem mass spectrometry ; solid phase extraction

Sažetak
An analytical method for multi-class pharmaceuticals determination in wastewater has been developed and validated. Target compounds were: sulfonamides (sulfadiazine, sulfaguanidine, sulfamethazine, sulfamethoxazole), fluoroqinolones (ciprofloxacine, enrofloxacine, norfloxacine), diaminopyrimidine (trimethoprim), anesthetic (procaine), anthelmintic (praziquantel and febantel) and macrolide (roxithromycine). The method involves pre-concentration and clean-up by solid phase extraction (SPE) using Strata-X extraction cartridges at pH 4.0. Target analytes were identified and quantitatively determined by liquid chromatography-tandem mass spectrometry using multiple reaction monitoring (MRM). Recoveries were higher than 50% with relative standard deviation (RSD) below 18.3 % for three concentration levels. Only for sulfaguanidine low recovery was obtained. Matrix effect was evaluated using matrix-matched standards. The method detection limit (MDL) was between 0.5 and 5 ng/L in spiked water samples. The precision of the method, calculated as relative standard deviation, ranged from 0.5 to 2.0% and from 1.4 to 8.3 for intra- and inter-day analysis, respectively. The described analytical method was applied for determination of pharmaceuticals in effluent wastewaters from pharmaceutical industry.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
MZOS-125-1253008-1350 - Razvoj naprednih analitičkih metoda za određivanje farmaceutika u okolišu (Babić, Sandra, MZOS ) ( CroRIS)
MZOS-125-2120898-3148 - Hrvatsko nazivlje u analitičkoj kemiji (Kaštelan-Macan, Marija, MZOS ) ( CroRIS)

Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb

Poveznice na cjeloviti tekst rada:

doi dx.doi.org link.springer.com

Citiraj ovu publikaciju:

Babić, Sandra; Mutavdžić Pavlović, Dragana; Ašperger, Danijela; Periša, Martina; Zrnčić, Mirta; Horvat, Alka J.M.; Kaštelan-Macan, Marija
Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS) // Analytical & bioanalytical chemistry, 398 (2010), 3; 1185-1194 doi:10.1007/s00216-010-4004-1 (međunarodna recenzija, članak, znanstveni)
Babić, S., Mutavdžić Pavlović, D., Ašperger, D., Periša, M., Zrnčić, M., Horvat, A. & Kaštelan-Macan, M. (2010) Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Analytical & bioanalytical chemistry, 398 (3), 1185-1194 doi:10.1007/s00216-010-4004-1.
@article{article, author = {Babi\'{c}, Sandra and Mutavd\v{z}i\'{c} Pavlovi\'{c}, Dragana and A\v{s}perger, Danijela and Peri\v{s}a, Martina and Zrn\v{c}i\'{c}, Mirta and Horvat, Alka J.M. and Ka\v{s}telan-Macan, Marija}, year = {2010}, pages = {1185-1194}, DOI = {10.1007/s00216-010-4004-1}, keywords = {pharmaceuticals, wastewater, liquid chromatography-tandem mass spectrometry, solid phase extraction}, journal = {Analytical and bioanalytical chemistry}, doi = {10.1007/s00216-010-4004-1}, volume = {398}, number = {3}, issn = {1618-2642}, title = {Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS)}, keyword = {pharmaceuticals, wastewater, liquid chromatography-tandem mass spectrometry, solid phase extraction} }
@article{article, author = {Babi\'{c}, Sandra and Mutavd\v{z}i\'{c} Pavlovi\'{c}, Dragana and A\v{s}perger, Danijela and Peri\v{s}a, Martina and Zrn\v{c}i\'{c}, Mirta and Horvat, Alka J.M. and Ka\v{s}telan-Macan, Marija}, year = {2010}, pages = {1185-1194}, DOI = {10.1007/s00216-010-4004-1}, keywords = {pharmaceuticals, wastewater, liquid chromatography-tandem mass spectrometry, solid phase extraction}, journal = {Analytical and bioanalytical chemistry}, doi = {10.1007/s00216-010-4004-1}, volume = {398}, number = {3}, issn = {1618-2642}, title = {Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS)}, keyword = {pharmaceuticals, wastewater, liquid chromatography-tandem mass spectrometry, solid phase extraction} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • CA Search (Chemical Abstracts)


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font