Pregled bibliografske jedinice broj: 463710
Analysis of Different Containment Models for IRIS Small Break LOCA using GOTHIC and RELAP5 codes
Analysis of Different Containment Models for IRIS Small Break LOCA using GOTHIC and RELAP5 codes // Nuclear engineering and design, 241 (2011), 4; 1152-1164 doi:10.1016/j.nucengdes.2010.06.016 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 463710 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Analysis of Different Containment Models for IRIS Small Break LOCA using GOTHIC and RELAP5 codes
Autori
Papini, Davide ; Grgić, Davor ; Cammi, Antonio ; Ricotti, Marco E.
Izvornik
Nuclear engineering and design (0029-5493) 241
(2011), 4;
1152-1164
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
IRIS; small break LOCA; GOTHIC; RELAP
Sažetak
Advanced nuclear water reactors rely on containment behaviour in realization of some of their passive safety functions. Steam condensation on containment walls, where non-condensable gas effects are significant, is an important feature of the new passive containment concepts, like the AP600/1000 ones. In this work the international reactor innovative and secure (IRIS) was taken as reference, and the relevant condensation phenomena involved within its containment were investigated with different computational tools. In particular, IRIS containment response to a small break LOCA (SBLOCA) was calculated with GOTHIC and RELAP5 codes. A simplified model of IRIS containment drywell was implemented with RELAP5 according to a sliced approach, based on the two-pipe-with-junction concept, while it was addressed with GOTHIC using several modelling options, regarding both heat transfer correlations and volume and thermal structure nodalization. The influence on containment behaviour prediction was investigated in terms of drywell temperature and pressure response, heat transfer coefficient (HTC) and steam volume fraction distribution, and internal recirculating mass flow rate. The objective of the paper is to preliminarily compare the capability of the two codes in modelling of the same postulated accident, thus to check the results obtained with RELAP5, when applied in a situation not covered by its validation matrix (comprising SBLOCA and to some extent LBLOCA transients, but not explicitly the modelling of large dry containment volumes). The option to include or not droplets in fluid mass flow discharged to the containment was the most influencing parameter for GOTHIC simulations. Despite some drawbacks, due, e.g. to a marked overestimation of internal natural recirculation, RELAP5 confirmed its capability to satisfactorily model the basic processes in IRIS containment following SBLOCA.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
Napomena
Rad je prezentiran 2009.g. na skupu International Conference on Nuclear Energy for New Europe ; Leon Cizelj, Yassin Hassan, Borut Mavko (ur.)
POVEZANOST RADA
Projekti:
036-0361590-1589 - Nuklearne elektrane za održivu proizvodnju električne energije (Feretić, Danilo, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb
Profili:
Davor Grgić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus