Energy-economic analysis of CHP turbine with three-stage heating of district heating system water
Energy-economic analysis of CHP turbine with three-stage heating of district heating system water // CD Proceedings of ECOS 2009 / Nebra, Silvia Azucena ; de Oliveira Junior, Silvio ; Bazzo, Edson (ur.).
São Paulo: ABCM - The Brazilian Society of Mechanical Sciences and Engineering, 2009. str. 687-698 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 462418 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Energy-economic analysis of CHP turbine with three-stage heating of district heating system water
Autori
Guzović, Zvonimir ; Jukić, Perica ; Lončar, Dražen
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
CD Proceedings of ECOS 2009
/ Nebra, Silvia Azucena ; de Oliveira Junior, Silvio ; Bazzo, Edson - São Paulo : ABCM - The Brazilian Society of Mechanical Sciences and Engineering, 2009, 687-698
Skup
22nd International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems
Mjesto i datum
Foz do Iguaçu, Brazil, 31.08.2009. - 03.09.2009
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
cogeneration power plant ; CHP steam turbine ; district heating ; energy-economic analysis
Sažetak
Today the district heating is predominantly based on cogeneration power plants with steam turbines for combined heat and power production (CHPT) with controlled steam extractions (CE). In case of stagewise heating of district heating system water, the whole heating is realised in a number of successively connected water heaters by steam extracted from the turbine. This results in additional production of electric power because heating steam extracted for the first stage in the direction of system water flow, has lower pressure than for the second stage. In CHPTCE when operating in heating load regimes, the steam flow to the condenser still is not permitted to be zero. There is minimal steam flow rate which is required for the cooling of the low-pressure stages. For recovering this heat, the condenser has additional built-in bundle tubes, which can be fed with returned system water from district heating. On this way the built-in bundles in condensers of CHPTCE make the third stage of stagewise heating of system water. The paper objective is to determine feasibility of the three-stage heating of system water by Cleaner Production Methodology on example of CHPTCE of 120 MW power installed in the Cogeneration Power Plant Zagreb (TE-TO Zagreb). The results of the energy and economic analysis show high feasibility of the three-stage system water heating application.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Projekti:
MZOS-120-1201775-1777 - Optimiranje korištenja vjetropotencijala u vjetroelektrani (Tuković, Željko, MZOS ) ( CroRIS)
MZOS-120-1201775-3318 - Optimiranje vodnih turbina za male hidroelektrane (Guzović, Zvonimir, MZOS ) ( CroRIS)
MZOS-120-1201918-1911 - Optimiranje uvođenja novih tehnologija u regionalni energetski sustav (Bogdan, Željko, MZOS ) ( CroRIS)
MZOS-120-1201918-1920 - Racionalno skladištenje energije za održivi razvoj energetike (Duić, Neven, MZOS ) ( CroRIS)
Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb